6.4.4
DIC-4-045 to 120 frequency inverters
Fig. 14
CAUTION
Hot components due to insufficient cooling
Risk of burns on contact and fire hazard
The units must be fitted with sufficient clearance to allow cooling air to circulate without any hindrance.
Ensure that air pollution from sources such as dust, greases, aggressive gases, etc., is avoided.
Size 5 and 6 frequency inverters are supplied with a mounting frame which is attached to the heat sink. The unit is
fastened by cheese-head screws at the top and bottom and by counter-sunk screws on the sides. M6 screws
must be used for attaching size 5 units to the mounting panel, and M8 screws for size 6.
Frequency inverter
Size 5 DIC-4-045 ... 060
Size 6 DIC-4-075 ... 120
Tab. 27
34
a
b
c
250
200
265
400
275
265
Dimensions in mm
a1
a2
270 ... 290
315
430 ... 450
470
b1
c1
160
165
235
165