Dic-2-018 And Dic-4-014 To 040 Frequency Inverters; Dic-X-Xxx-E - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

6.4.3

DIC-2-018 and DIC-4-014 to 040 frequency inverters

6.4.3.1

DIC-x-xxx-E

x ≥ 100 mm
x ≥ 100 mm
Fig. 12
CAUTION
Hot components due to insufficient cooling
Risk of burns on contact and fire hazard
The units must be fitted with sufficient clearance to allow cooling air to circulate without any hindrance.
Ensure that air pollution from sources such as dust, greases, aggressive gases, etc., is avoided.
Install the unit on the mounting panel with the standard fasteners.
Install the unit by bolting the two angle brackets to the heat sink of the frequency inverter and the mounting panel.
Size 3 and 4 frequency inverters are supplied with angle brackets which are bolted to the heat sink by four screws
each. The upper angle brackets are fixed with M4x20 screws, the lower angle brackets with M4x60 screws.
Frequency inverter
Size 3 DIC-2-018 and DIC-4-014 ... 017
Size 4 DIC-4-025 ... 040
Tab. 25
32
m
a
b
250
100
250
125
t
Dimensions in mm
c
a1
200
270 ... 290
200
270 ... 290
a2
b1
c1
m
315
76
133
6,5
315
90
133
6,5
t
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dic 210 seriesDic 120 series

Table of Contents