General Information On Commissioning - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

7.2

General information on commissioning

Drive control
The inverter is controlled via terminal strips X210A and X210B.
Implementation
The inverter is supplied with its parameters set to default values.
See  "Parameters/functions", Page 64 for a description of the parameters and functions.
Refer to "Dedrive Compact STO frequency inverter application notes/operating instructions" for a list of all pa‐
rameters.
Check when commissioning:
Control signals (depending on the control mode),
Motor thermal contact,
Enable signal connection,
Motor/inverter configuration,
Direction of rotation,
Speeds (v
Ramps (acceleration and deceleration).
If the drive behaves according to the specifications of your installation, commissioning is complete. If the drive
operating characteristics need to be corrected, modify the parameters in consultation with your project engineer.
The parameters of the inverter can either be programmed via the KP500 keypad unit (see  "Programming pa‐
rameters with the KP500 keypad unit", Page 53) or by using the Parcom Compact parameter programming soft‐
ware (see  "Programming parameters with Parcom Compact software", Page 56).
52