Diagnosis; General; Status Display - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

9

Diagnosis

9.1

General

Operation of the frequency inverter and the connected load is continuously monitored.
For further information, see "Dedrive Compact STO frequency inverter application notes/operating instructions".
9.2

Status display

Fig. 48
The red and green LEDs provide information on the operating point of the frequency inverter. If the keypad unit is
plugged in, status messages are also displayed by display elements RUN, WARN and FAULT.
Status display
Green LED
Red LED
Off
Off
On
On
Flashing
Off
Flashing
Off
On
Off
On
Flashing quickly
Flashing
Flashing quickly
Off
Flashing
Off
On
Tab. 81
Display
-
- No power supply
- If the supply voltage is applied to L1, L2, L3, a serious device error has occurred. Please contact
Demag Cranes & Components GmbH after-sales service.
-
Brief initialisation and Self-Test after the power supply is switched on.
RUN flashing
With S1IND/STO A and S7IND/STO B=LOW: ready, no modulation possible since there is no con‐
trol enable.
RUN flashing
With S1IND/STO A and S7IND/STO B=HIGH: Ready, control enable on; no modulation, since
there is no travel command at SW-Step 1+ or 1-.
RUN
Operating message, inverter output active.
RUN + WARN
Operating message, there is a warning, see Warnings 269
RUN flashing
Ready, there is a warning, see Warnings 269
slowly + WARN
FAULT flashing
An error has occurred. See KP500 display or Current error 259.
slowly + WARN
The error cannot be acknowledged because the cause of the error has not been eliminated.
FAULT
An error has occurred. See KP500 display or Current error 259, error can be acknowledged.
Description
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dic 210 seriesDic 120 series

Table of Contents