Programming Parameters With The Kp500 Keypad Unit; Key Assignment And Displays - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

7.3

Programming parameters with the KP500 keypad unit

7.3.1

Key assignment and displays

Fig. 32 Key assignment and displays
Parameters can be set and displayed and the frequency inverter can be controlled by means of the optional
KP500 keypad unit. The keypad unit is not absolutely essential for operation of the frequency inverter and can be
plugged in during operation, as required.
A
RUN
see "Dedrive Compact STO frequency inverter application notes/operating instructions"
STOP
J
- Navigate the menu structure.
- Select parameters.
- Increase and decrease parameter values.
▲ + ▼
Simultaneously press the ▲ + ▼ keys for Special Functions.
ENT
Call parameters or change within the menu structure. Confirm the selected function or parameter.
ESC
Exit parameters or return within the menu structure. Abort the function or reset the parameter value.
FUN , ▲
Press the keys one after the other:
FUN , ▼
- Change key function.
FUN , ENT
B
Three-digit 7-segment display to show the parameter numbers.
Parameter nos. > 999 are shown from 1000 = a00 to 1599 = f99.
C
One-digit 7-segment display of the active data set, direction of rotation, etc.
D
Display the selected menu branch:
VAL
Display Actual Values
PARA
Select parameters and edit parameter values
CTRL
Select functions which can be used via the keypad unit:
SEtUP: guided set-up, see  "Setup", Page 58
CtrL: see "Dedrive Compact STO frequency inverter application notes/operating instructions"
PArID: as for SEtUP, however, without setpoint values
E
Status and mode messages:
WARN
Warning against critical operating behaviour
FAULT
Error-Switch-Off with the associated message
RUN
Flashing: indicates readiness for operation
Continuously on: indicates operation and release of the output stage
REM
Active remote control via interface connection
(CtrL cannot be selected if REM is active)
F
Change functions using the
F
Five-digit 7-segment display of the parameter value and sign
G
Physical unit of the parameter value displayed
H
Active acceleration or deceleration ramp
I
Current direction of rotation of the drive
Tab. 50
Keys
Screen
key
FUN
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dic 210 seriesDic 120 series