6.4.2

DIC-2-003 to 010 and DIC-4-002 to 009 frequency inverters

6.4.2.1

DIC-x-xxx-E

x ≥ 100 mm
x ≥ 100 mm
Fig. 10
CAUTION
Hot components due to insufficient cooling
Risk of burns on contact and fire hazard
The units must be fitted with sufficient clearance to allow cooling air to circulate without any hindrance.
Ensure that air pollution from sources such as dust, greases, aggressive gases, etc., is avoided.
Install the unit with the standard fasteners in a vertical mounting position on the mounting panel.
Install the inverter on the line filter using the mounting bracket included in the line filter scope of supply.
Install the unit by inserting the long side of the retaining plate into the heat sink and bolting it to the mounting
panel.
Frequency inverter
Size 1 DIC-2-003 ... 005 and DIC-4-002 ... 004
Size 2 DIC-2-010 and DIC-4-006 ... 009
Tab. 23
30
m
t
a
b
c
190
60
180
250
60
180
Dimensions in mm
a1
a2
b1
210 ... 230
255
30
270 ... 290
315
30
c1
m
t
130
6,5
2
130
6,5
2