Control Terminals - DEMAG DIC 002 Series Operating Instructions Manual

Table of Contents

Advertisement

6.5.10

Control terminals

Fig. 29
Control terminals
1
Control terminals
2a
Rigid cable
2b
Flexible cable
2c
With wire end ferrule without plastic sleeve
2d
With wire end ferrule with plastic sleeve
Tab. 43
The control and software functions can be freely configured to ensure safe and efficient operation. The quick-step
operating instructions describe the default settings.
The inputs and outputs can be supplemented by an EM – UNI-01 unit.
CAUTION
Incorrect connection/disconnection of the control terminals
Damage to/malfunction of the frequency inverter
No power must be applied to the control inputs and outputs which are protected against polarity reversal when
they are connected and disconnected.
Description of control terminal X210A
Terminal
Connection
X210A.1
Voltage input and output
X210A.2
Ground / GND
X210A.3
Digital Input S1IND
X210A.4
Digital Input S2IND
X210A.5
Digital Input S3IND
X210A.6
Digital Input S4IND
X210A.7
Digital Input S5IND
Tab. 44
For further information, see  "Block diagram", Page 40.
18)
The power supply on terminal X210A.1 can be loaded with a max. current of I
current is reduced by digital output S1OUT and Multi-function Output MFO1.
19)
The level must be 24 V. For configurations, see  "Setup", Page 58. Please note  "Information on the pulse generator", Page 41 for the
48
rotary encoder cable.
DIC-x-002 to 210
Wieland DST85 / RM3,5
0,14 ... 1,5 mm
; AWG 30 ... 16
2
0,14 ... 1,5 mm
; AWG 30 ... 16
2
0,25 ... 1,0 mm
; AWG 22 ... 18
2
0,25 ... 1,0 mm
; AWG 22 ... 18
2
Electric data
18)
24 V, I
= 180 mA
max
0 V
U
= 30 V, 10 mA at 24 V
PLC-compatible
max
Explanation/Use (default)
Supply voltage, see  "External 24 V power supply",
Page 41
See  "External 24 V power supply", Page 41
STO A controller release / acknowledge fault
programmable, SW-Step 1+
programmable, SW-Step 1-
programmable,
Encoder 1 track B possible
programmable,
Encoder 1 track A possible
= 180 mA. Depending on the application, the max. available
max
19)
19)