EM extension module installation instructions
Remove the cover before installing the extension module in slot C.
Only AC may be applied to semi-conductor relay EM-S1OUTD on terminal X412 of extension module EM –
UNI-01. DC loads can result in dangerous malfunctions.
Digital outputs EM-S1OUTD and EM-S2OUTD on terminal X410A of the EM – ABS-01 extension module must
not be programmed with the "41 - Release brake" and "103 – Inv. Error" function parameters. Dangerous mal‐
functions can occur. These settings are blocked for EM – ABS-01 modules for software version 5.4.2/050-11 and
higher.
CM communication module installation instructions
Fig. 9
A PE spring is also included to connect the PE conductor (screen).
Installing the CM communication module
1.
Remove the cover.
2.
The slot for the module sub-assembly is accessible.
3.
First install the PE spring included in the delivery using the screw fitted in the unit.
The spring must be centred when fitted.
4.
The unit can now be fitted and secured to the PE spring using the spring on the module.
5.
Break out the pre-stamped opening in the cover for connector X310 and refit the cover.
28