8.5.3

Function assignment of the relay and digital outputs

Available:
● 1 digital output with transistor output Op. Mode Digital Output 1 S1OUT 530;
● 1 relay output with changeover contact Op. Mode Digital Output 3 S3OUT 532;
● 1 multi-function output, digital assignment possible Operation Mode digital MFO1D 554.
Message "Ready"
The inverter indicates it is ready for operation by activating a programmable output. Reference values are only
processed in Ready mode (Op. Mode Digital Output 1 S1OUT 530 on terminal X210B.3 by default).
The inverter is not ready in the following situations:
● After the power supply has been switched on, during the initialisation phase.
● After the power supply has been switched off, after the internal supply voltage has dissipated (after approx. 0,5
to 5 sec.).
● If there is no release signal.
● If an error has been detected and the error response process is running.
● If an error has not been acknowledged.
"Modulation on" message
The programmed output is activated when the inverter output is active.
Message "Error"
The programmed output is switched to active mode if an error occurs. The output remains active until the error
has been acknowledged (Operation Mode digital MFO1D 554 on terminal X210B.4 by default).
"Warning, General" message
The message is displayed via the Warnings 269 parameter.
"Release brake" signal
The inverter provides further parameters for synchronisation of a separate brake.
Due to its higher voltage load rating up to 230 V, a power contactor for control of the external brake can be con‐
trolled direct with relay 3 (Op. Mode Digital Output 3 S3OUT 532 on terminal X10 by default).
Alternatively, the brake can be controlled by AC control voltage via the
Op. Mode Digital Output 4 EM-S1OUTD 533 parameter on terminal X412 of the EM – UNI-01 extension
module.
The benefit in this case is wear-free control via a semi-conductor output (solid state relay).
The Op. Mode Digital Output 4 EM-S1OUTD 533 und Op. Mode Digital Output 5 EM-S2OUTD 534
parameters on terminals X410A.3 and X410A.4 of the EM – ABS-01 extension module must not be used for the
"Release brake" function.
See page 10 for further information.
For further information, refer to the "EM – UNI-01 extension module" operating instructions.
Setting
Unit
Min.
Control Inputs/Outputs ➜ Digital Inputs
Explanation
Max.
Default
71 - S2IND
72 - S3IND
75 - S6IND
75 - S6IND