8. Mechanical parts
8-1-2. Paper feed motor and its gear train
(Reference to Fig. 5-14)
8-1. Paper feed mechanism
Disassembly procedure
(1) Remove the top cabinet assy, in reference to Paragraph upper
8-1-1. Platen and pressure rollers (Ref. to Fig. 5-12)
cabinet assy.
Disassembly procedure
(2) Remove the platen, in reference to Paragraph 8-1-1 Platen and
(1)
Remove the top cabinet assy, in reference to paragraph upper
pressure rollers.
cabinet assy.
ai
(3)
Remove the paper feed motor cable from the control PWB.
(2)
Press the platen @ in the arrow direction (A) and remove it from
the frame @ as shown with the arrowhead (8).
(4)
Remove the two paper feed motor screws (B2) and (B3), then
(8) Lift the feed roll holder ® up in the arrow direction (C) to
remove the paper feed motor © from the frame @.
remove.
(5) Pull the idler gear ® in the direction of the arrow (D) to remove it
(4)
Remove the release spring ©, then remove the feed roll holder
from the frame @.
support ©.
(6) Remove the PF spring @ and the screw (B4) from the frame @.
Reassembly procedure
=
(7) As shown in Fig. 5-14 press the latch (E) of the lever © with
Observe the reverse sequence of the disassembly procedure.
fingers in the direction of (F) while holding the PF holder @, and
push it in the direction of the arrow (G) to remove both the PF
holder @ and the lever ®.
IFig. 5-12]