Single-pulse the remote input.
Midpoint TEACH
Output ON
Output OFF
Window Size
The D_OUT › TchMid › WndSize option sets the window size that the Midpoint TEACH uses to set the setpoint one and set-
point two thresholds.
The taught surface must be inside the defined sensing range, and at least one setpoint (with offset applied, if any) must be lo-
cated within the sensing range.
Parameters
Window Size Minimum
Window Size Maximum
Range
Default Window Size
Remote Input: Available
Access the setup mode.
1.
Method
Push Button
Remote Input
Set the window size.
2.
June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
Action
Window and Midpoint Example
0 mm
Midpoint
(600 mm)
SP1
SP2
(500 mm)
(700 mm)
10 mm
11950 mm
50 mm to 12000 mm
20 mm
a. Double-pulse the remote input to enter set-
up mode.
b. Three-pulse the remote input to enter win-
dow size mode.
T
The Midpoint TEACH uses both the window size and the
TEACH midpoint to determine the actual measurement win-
dow. For example, a window of 200 mm with a midpoint of 600
mm places the measurement window from 500 mm to 700
mm.
To use Midpoint TEACH:
Set the window size.
1.
1000 mm
2.
Set the measurement window using "TEACH Mid-
point " on page
LTF12
Action
T
T
T
© Banner Engineering Corp.
Result
"TchSPt2 Teaching" displays while the sen-
sor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and the sensor re-
turns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step 2,
and "RMT TCH" displays.
20.
LTF24
10 mm
23950 mm
50 mm to 24000 mm
20 mm
Result
"WndSize" and the current window
size value display.
T
a. "REMOTE SETUP" displays.
T
b. "WndSize" and the current value
T
T
display.
T