Remote Input: Not available 
Default: 50 mm 

Mode

The Mode option sets the output to the desired mode. 
 Navigate:MENU › Dx_OUT › Mode 
Remote Input: Available 
Default: Wnd 
The following table describes the sensor modes. 
Mode 
Alarm 
Health 
 Switch
 
  Switch
 
Wnd 
 
Wnd 
 
PFM
 
 Remote Input Instructions
Access the setup mode.
1.
Double-pulse the remote input. 
View the current mode.
2.
June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
 mode 
Alarm Mode: The Discrete Output is Off while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is On. 
This mode has no associated thresholds. 
Health Mode: The Discrete Output is On while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is Off. 
This mode has no associated thresholds. 
Switch Mode: The Discrete Output is On while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is Off. 
Switch Mode: The Discrete Output is Off while a target is detected nearer than the switch point threshold.
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is On. 
Window Mode: The Discrete Output is On while a target is detected between the SPt1 and SPt2 thresholds. (Default)
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is Off. 
Window Mode: The Discrete Output is Off while a target is detected between the SPt1 and SPt2 thresholds.
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is On. 
 The discrete is pulsed at a frequency between 100 Hz and 600 Hz and is scaled proportional to the sensor's 
D2_OUT Measurement span. Targets outside of the measurement span or a loss of signal pulse at 50 Hz. 
Action 
Description 
 
T
T
T
 
© Banner Engineering Corp.
Result 
"REMOTE SETUP" displays. 
 
23