Navigate: MENU › D_OUT › SPtRef
Remote Input: Not available
Default: Object
Switch Point TEACH Offset
Use this menu to set an offset from the taught distance after a switch point TEACH, if SPtRef is set to Custom.
By default, the value is 0 mm. A positive offset value always shifts the threshold towards the sensor.
Navigate: MENU › Dx_OUT › TchMd › Offset
Remote Input: Not available
Default: 0 mm
Switch Point Hysteresis
With the default setting of AUTO, the hysteresis value applied at each threshold is automatically calculated and set based on
target, distance and measurement repeatability, with a 10 mm minimum setting.
By default, the hysteresis is applied away from the sensor. Changing the SPt Ref setting from Object to Background changes
the direction of the hysteresis.
How hysteresis affects the sensor output based on the discrete output switchpoint mode and the setpoint reference mode
June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
Object
On
(Object)
Off
On
Background
(Backgrnd)
Off
Near
How hysteresis affects the two discrete output window modes
Wnd
Hyst
Hyst
On
Off
Near
SPt1
SPt2
Mode
Swtch
Hyst
Hyst
SPt
Far
Mode
On
Off
Far
Near
© Banner Engineering Corp.
Swtch
On
Off
Hyst
Hyst
On
Off
SPt
Near
Far
Wnd
Hyst
Hyst
SPt1
SPt2
Far
25