LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
Method
Push Button
Remote In-
put (Sets
A_OUT and
D_OUT window
Size)
TEACH Midpoint
The TchMdPt option sets the midpoint that determines the actual measurement window.
Navigate: MENU › Dx_OUT › TchMid › TchMdPt
Remote Input: Available
Button Instructions
Present the target.
1.
Present the target.
Access the TEACH midpoint mode and TEACH the sensor.
2.
Navigate: MENU › Dx_OUT › TchMid › TchMdPt
Remote Input Instructions
Access the TEACH mode.
1.
Single-pulse the remote input.
Present the target.
2.
20
Action
a. Use Down and Up to set the desired window size—the value
changes in increments of 2.
b. Press Enter to save the new value.
Pulse the remote input 1 to 6 times to select the desired window size.
1 pulse: 10 mm
2 pulses: 20 mm
3 pulses: 100 mm
4 pulses: 500 mm
5 pulses: 2000 mm
6 pulses: 11950 mm for the LTF12; 23950 mm for the LTF24
Action
Action
Action
© Banner Engineering Corp.
a. "WndSize" and the new value dis-
play.
b. The new value flashes and returns
to "TchMid WndSize".
The new value flashes and the sensor
returns to Run mode.
The target's distance measurement value
displays.
"TchMdPt Teaching" displays while the sen-
sor is being taught.
TEACH Accepted
The new value is shown on the second line
of the display and flashes before it is saved
and the sensor returns to "TchMid Tch-
MdPt".
TEACH Not Accepted
"FAIL" and a warning message display, and
the sensor returns to "TchMid TchMdPt".
"RMT TCH" and the current measurement
T
value display.
Result
Result
Result
Result
June 22, 2023