How hysteresis affects the output on/off points when if the sensor is configured with mode = Swtch_|- and SPtRef configured
Press the up button to manually select a constant hysteresis value between 2 mm and 12000 mm.
Navigate: MENU › D_OUT › Hyst
Remote Input: Not available
Default: Auto
Timer
The Timer option sets the delays and timers. On/Off Delays and On/Off One-Shot timers can be programmed between 1 to
9999 ms (a value of 0 disables the delay/timer). The following figure defines how the delays/timers affect the output behavior.
Navigate: MENU › Dx_OUT › Timer
Remote Input: not available
Default: 0 ms for all timers
Output
OFF Delay
OFF 1-Shot
D
ON Delay
D
ON 1-Shot
Some combinations of delays/timers are not allowed. The programming menu automatically disables invalid combinations of delays/timers. The following ta-
ble shows the allowable combinations of delays/timers.