Air temperature correction
1. Press
to select the air temperature
2. Use
and
to set the air temperature value.
3. Validate the selection
Water temperature correction
1. Press
to select the water temperature
2. Use
and
to set the water temperature value.
3. Validate the selection
Conductivity unit (g/l or μS)
1. Press
to select the conductivity unit
2. Use
and
to change the unit.
3. Validate the selection
4. Return the switch to the ON mode (rear side of the Inner Display).
Calibration of a pH probe
Due to its nature, a pH probe needs to be recalibrated regularly (preferably before the season).
The pH Probe Pentair is available as a spare part from your dealer Pentair.
Tools
• pH probe;
• Inner Display;
• standard bottles of pH4 and pH7.
What to do
ü This procedure needs to be practiced in the shade.
Ref. SB-CU-IMP-062EBA / A - 11.05.2023
Installation and Operation Guide Version E-Box MAESTRO - Programming
to validate the air temperature value.
to validate the water temperature value.
to validate the conductivity unit.
.
.
.
85 / 110