+12V
Phase 230V
Neutral 230V
4.11.2
PENTAIR VS2 and VS2 m
Info
On the pump, set: speeds 1 < 2 < 3 < 4
• Activate the "Ext. Control Only "(see pump manual)
• Switch on the filter pump through the "Start/Stop" button
IN bypass connections
Not plugged in: No bridging to be performed on the IN inputs of the Speed FC
Operation
• Speed 1: Frost free: Outlet used to trigger filtration for a water temperature < +3°C
(modifiable).
• Speed 2: Eco: Speed used for filtration when the pool is little used or in the middle of the
season.
• Speed 3: Normal: Speed used for filtration when the pool is used and/or in hot season.
• Speed 4: Maximum: Speed used for backwashing.
Connections
• Common control cable: 30-32-34-36
Ref. SB-CU-IMP-062EBA / A - 11.05.2023
-0V
Installation and Operation Guide Version E-Box MAESTRO - Installation
BUS link
Intelliflo CABLE
V1
V2
V3
V4
57 / 110