Pentair E-Box MAESTRO Installation And Operation Manual page 77

Table of Contents

Advertisement

2.
The pH has reached alarm
value
3.
Measured pH value
4.
Alarm setpoint
compliance
The pH is a quantity (without units) measuring the acidity (0 to 7) or alkalinity (7 to 14) of the basin.
The pH is the concentration of hydrogen ions. For a swimming pool, the ideal pH generally
recommended is close to 7.3 (to be confirmed with your pool owner depending on your
installation).
Tip
The accuracy of the pH measurement is related to the regular maintenance of the pH
probe. It is advisable to check it regularly for any contamination (see Cleaning the pH or
RedOx probe [
mode [
Page 84]).
Info
The set values of the high and low pH alarms are factory pre-set to 6.7 and 7.9. These
values can be modified through the alarm mode (see Alarm mode [
Ref. SB-CU-IMP-062EBA / A - 11.05.2023
the pH has reached the maximum alarm value
(factory pre-set at 6.7 can be modified through the alarm
menu, see Alarm mode [
the pH has reached the minimum alarm value
(factory pre-set at 7.9 can be modified through the alarm
menu, see Alarm mode [
• Limited display between 0 and 9.9
• Display out-of-limit value:
pH according to alarm setpoints
(factory pre-set from 6.7 to 7.9)
("min" and "max" indicate if the value is too low or too
high)
Page 96] and to calibrate it before the summer season (see Calibration
ACID
Installation and Operation Guide Version E-Box MAESTRO - Programming
pH < 0
pH > 9.9
pH outside the alarm setpoint values
IDEAL
Page 81])
Page 81])
Page 81]).
BASIC
77 / 110

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sb-pf-ens-002e

Table of Contents