Speed-Fc; Pentair Intelliflo Vsd2, Vsf - Pentair E-Box MAESTRO Installation And Operation Manual

Table of Contents

Advertisement

Installation and Operation Guide Version E-Box MAESTRO - Installation
2. In the menu "Pool Properties > Menu Installation 4X Extension", see Menu installation 4X
Extension [
Page 48], select the output AUX  2 "Filling" and customise the name if
necessary.
3. Connect the filling solenoid valve (24 V) to terminal blocks 51-52.
4. Connect the level sensor to the input IN 1 (or 2 or 3 or 4) and then, through the installation
menu, select the "water level NO" input
4.11

Speed-FC

4.11.1

PENTAIR IntelliFlo VSD2, VSF

Info
Set the appropriate Speed 1 (Frost Free), Speed 2 (Eco), Speed 3 (Normal) and Speed 4
(Max) speeds on the Drive (black control box on the Intelliflo pump).
IN bypass connections
Not provided: Requires the installation of an Intellicom V2 module and the driver cable.
Connections on the 4 "Speed" connectors/PENTAIR IntelliFlo + IntelliCom installation
• Frost free: Outlet used to trigger filtration for a water temperature < +3°C (modifiable).
• Eco Speed: Speed used when no preselected event (see relevant menu) is active.
• Normal speed: Speed used for the purposes of a preselected event (see relevant menu).
• Maximum speed: Speed used for backwashing or "shock" treatment (24  h of filtration and
electrolyser).
56 / 110
Does Not Fill
Ref. SB-CU-IMP-062EBA / A - 11.05.2023
Filled

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sb-pf-ens-002e

Table of Contents