Set Perimeter Protection Shield Region - HIKVISION DS-2TD2637T-7/P User Manual

Thermal kɖticăů bi-spectrum network camera
Table of Contents

Advertisement

Thermal Optical Bi-spectrum Network Camera User Manual
Background Interference Suppression
Eliminate the environment interference to reduce the false alarm. For example, the false
alarms caused by wind blowing grass.
Note
The parameter is available in optical channel.
Filter by Pixel
Check to enable Filter by Pixel. Draw max. size and min. size rectangles to filter the target
among human, vehicle, animal, and others. Only the target whose size is between the Max.
Size and Min. Size value will trigger the alarm.
Note
The filter configuration is optional for some camera models, refer to the pop-up
operation guide after you checked Intelligent Analysis.
You can draw the max. size and min. size rectangles according to the real target in the
scene. The recommended size is 1.2 times of the target.
5) Repeat steps above to configure other rules.
Note
You can click
6) Click Save.
5. Set Arming Schedule and Linkage Method Settings for each rule.
6. Optional: You can shield certain areas from being detected. Refer to Set Perimeter Protection
Shield Region for detailed settings.
7. Optional: Set displayed VCA information on stream or picture. Refer to Set Overlay & Capture
Parameters for detailed settings.
8. Optional: Calibrate the camera to improve the accuracy. Refer to Calibration for detailed
settings.

7.3.2 Set Perimeter Protection Shield Region

You can configure areas from being detected.
Steps
1. Go to Configuration → Local , and enable Display Shield Area.
2. Click
.
3. Drag the mouse in the live view to draw the area. You can drag the corners of the red rectangle
area to change its shape and size.
4. Right click the mouse to stop drawing.
5. Optional: Select one area and click
6. Click Save.
to copy the same settings to other rules.
to delete it.