Set Expert Mode
Select the temperature measurement rules from Point, Line, or Area and configure parameters,
the device alarms if the alarm rules are met.
Steps
1. Go to Configuration → Temperature Measurement & Fire Prevention → Basic Settings , check
Enable Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement & Fire Prevention → Advanced Settings ,
select Expert.
4. Select and enable the temperature measurement rules. Please refer to Set Thermography Rule
for setting the rule.
5. Optional: Click Area's Temperature Comparison to set the alarm rules and the temperature.
6. Click Save.
The maximum temperature and thermography rules will be displayed on the live view.
Note
Go to Image → VCA Rules Display to adjust the font size and the temperature color of normal,
alarm and pre-alarm.
7. Enable the scan function of device, such as linear scan to monitor the scene.
Set Thermography Rule
Steps
1. Customize the rule name.
2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface
where the position to be measured.
Point Please refer to Point Thermography for detailed configuration.
Line
Please refer to Line Thermography for detailed configuration.
Area
Please refer to Area Thermography for detailed configuration.
3. Configure the temperature measurement parameters.
Emissivity
Set the emissivity of the target. The emissivity of the surface of a material is its effectiveness
in emitting energy as thermal radiation. Different objects have different emissivity. Refer to
Common Material Emissivity Reference to search for the target emissivity.
Distance
The distance between the target and the device.
Reflective Temperature