Kubota WSM 07-E3B Series Workshop Manual page 129

Table of Contents

Advertisement

07-E3B SERIES, WSM
Thermostat Valve Opening Temperature
1. Push down the thermostat valve and insert a string between the
valve and the valve seat.
2. Place the thermostat and a thermostat in a container with water
and gradually heat the water.
3. Hold the string to suspend the thermostat in the water. When the
water temperature rises, the thermostat valve will open, allowing
it to fall down from the string.
Read the temperature at this moment on the thermometer.
4. Continue heating the water and read the temperature when the
valve has risen by about 8 mm (0.3 in.).
5. If the measurement is not acceptable, replace the thermostat.
V2607-DI-E3B
Thermostat's
V2607-DI-T-E3B
valve opening
V3007-DI-T-E3B
temperature
V3307-DI-T-E3B
V2607-DI-E3B
Temperature at
V2607-DI-T-E3B
which thermostat
completely
V3007-DI-T-E3B
opens
V3307-DI-T-E3B
S-26
ENGINE
80 to 84 C
Factory
176 to 183 F
spec.
74.5 to 78.5 C
Factory
166.1 to 173.3 F
spec.
95 C
Factory
203 F
spec.
90 C
Factory
194 F
spec.
W1071639
KiSC issued 06, 2020 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents