PMBus COMMAND SUMMARY
Table 7. PMBus Commands Summary (NOTE: The Data Format Abbreviations are Detailed in Table 8)
CMD
COMMAND NAME
CODE DESCRIPTION
MFR_VOUT_PEAK
0xDD The maximum measured value of READ_
MFR_VIN_PEAK
0xDE The maximum measured value of READ_
MFR_TEMPERATURE_1_PEAK
0xDF The maximum measured value of external
MFR_READ_IIN_PEAK
0xE1
MFR_CLEAR_PEAKS
0xE3
MFR_READ_ICHIP
0xE4
MFR_PADS
0xE5
MFR_ADDRESS
0xE6
MFR_ADDRESS
0xE6
MFR_SPECIAL_ID
0xE7
MFR_IIN_CAL_GAIN
0xE8
MFR_FAULT_LOG_STORE
0xEA Command a transfer of the fault log from
MFR_INFO
MFR_IOUT_CAL_GAIN
0xDA SET AT FACTORY. Typical 0.36mΩ
MFR_FAULT_LOG_CLEAR
0xEC Initialize the EEPROM block reserved for
MFR_FAULT_LOG
0xEE
MFR_COMMON
0xEF
MFR_COMPARE_USER_ALL
0xF0
MFR_TEMPERATURE_2_PEAK
0xF4
MFR_PWM_CONFIG
0xF5
MFR_IOUT_CAL_GAIN_TC
0xF6
MFR_RVIN_CAL_GAIN
0xF7
MFR_TEMP_1_GAIN
0xF8
VOUT since last MFR_CLEAR_PEAKS.
VIN since last MFR_CLEAR_PEAKS.
Temperature (READ_TEMPERATURE_1)
since last MFR_CLEAR_PEAKS.
The maximum measured value of
READ_IIN command since last
MFR_CLEAR_PEAKS
Clears all peak values.
Measured supply current of the SV
Digital status of the I/O pads.
2
Sets the 7-bit I
C address byte, Ch 0 and 1
2
Sets the 7-bit I
C address byte, Ch 2 and 3
Manufacturer code representing the
LTM4683 and revision
The resistance value of the input current
sense element in mΩ.
RAM to EEPROM.
0x
Contact factory.
fault logging.
Fault log data bytes.
Manufacturer status bits that are common
across multiple ADI chips.
Compares current command contents
with NVM.
Peak internal die temperature since last
MFR_CLEAR_PEAKS.
Set numerous parameters for the DC/DC
controller, including phasing.
Temperature coefficient of the current
sensing element.
The resistance value of the V
element in mΩ.
Sets the slope of the external temperature
sensor.
For more information
TYPE
PAGED
R Word
R Word
R Word
R Word
Send Byte
pin
R Word
IN
R Word
R/W Byte
R/W Byte
R Word
R/W Word
Send Byte
R Word
Send Byte
R Block
R Byte
Send Byte
R Word
R/W Byte
R/W Word
pin filter
R/W Word
IN
R/W Word
www.analog.com
LTM4683
DATA
FORMAT UNITS NVM
Y
L16
V
N
L11
V
Y
L11
C
N
L11
A
N
N
L11
A
N
Reg
N
Reg
Y
N
Reg
Y
N
Reg
N
L11
mΩ
Y
N
Y
L11
mΩ
N
N
Reg
Y
N
Reg
N
N
L11
C
N
Reg
Y
Y
CF
ppm/
Y
˚C
N
L11
mΩ
Y
Y
CF
Y
DEFAULT
VALUE
PAGE
NA
120
NA
120
NA
120
NA
120
NA
113
NA
121
NA
117
0x4F
85
0x4E
85
0x4191
111
2.0
97
0xC200
NA
123
127
0.360
95
Typical
0xD017
NA
127
NA
123
NA
118
NA
122
NA
121
0x10
90
3900
95
0x0F3C
1000
92
0x03E8
0.995
98
0x3FAE
Rev. 0
53
Need help?