Setting Up 1D Color Uniformity - Christie Mirage SST-6P User Manual

Hide thumbs Also See for Mirage SST-6P:
Table of Contents

Advertisement

a) Use the Max Ambient Temperature slider to increase and decrease the maximum
ambient temperature you expect the room to reach and select Enter.
The system uses the maximum expected room temperature to calculate the light output
(Maser Laser Power). The default maximum expected room temperature setting is 25°
C. A lower room temperature generally results in increased brightness and better
efficiency. A higher room temperature reduces the maximum power setting available for
the lasers. The maximum expected room temperature setting must reflect the anticipated
operating conditions.
6. Select MENU > Image Settings > Color & Gamma > Color Correction Mode.
7. Select Max Drives and to confirm your selection, select Enter.
8. Select MENU > Configuration > Light & Output Settings.
9. To set the approximate red power level, select Red Laser Setpoint and use the slider to
increase and decrease the value required for your projection environment.
To turn off the red lasers but leave them in a ready state, select Red Laser Enable to clear
the checkbox.
10. To set the green (Green Laser Setpoint) and blue (Blue Laser Setpoint) power levels,
repeat step 9.
To turn off either the green or blue lasers but leave them in a ready state, select Green Laser
Enable or Blue Laser Enable to clear the checkbox.
11. If color is not at the target level, refine the red, green, and blue power settings to achieve the
target by repeating steps 9 and 10.
12. To control the brightness once the colors are set, select Maser Laser Power and use the
slider to increase or decrease the value.
To turn off all lasers but leave them in a ready state, select Maser Laser Enable to clear the
checkbox.
13. To save the new laser settings, save to a projector profile.

Setting up 1D color uniformity

Learn how to set up 1D color uniformity on the projector after taking measurement of each of the
color primaries at points (15, 2, 5, 8, and 16).
1. Ensure the projector is running in representative ambient light.
2. Setup a spectroradiometer, such as the CR-250, on a tripod.
If not using the CR-250 or better, Christie recommends placing the meter perpendicular to the
screen to achieve accurate measurements.
Do not use the PR-655 spectroradiometer to perform color uniformity on a multi-projector
installation.
3. Power on the projector.
4. Allow the light source to stabilize.
5. From the side panel home page, use the arrows to select Test Pattern.
6. Select the 17 Point test pattern and to confirm your selection, select Enter.
Mirage SST User Guide
020-102993-06 Rev. 1 (10-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
Configuring system settings
41

Advertisement