Here is an example of an answer from the XML service:
LISTING THE MONITORING VALUES OF A KVM SWITCH
<?xml version="1.0" encoding="utf-8"?>
<root>
<result type="monitor">
<DlMux4>
<item>
<id>0x11111111</id>
<name>MUX-NT</name>
<monitorName>Status</monitorName>
<value>1</value>
<alarm>off</alarm>
<acknowledged>no</acknowledged>
</item>
</DlMux4>
</result>
</root>
NOTE:
In addition to the name and value of the respective monitoring value, the
two flags
acknowledged
flags to determine whether the monitoring value is within (
required range.
Acknowledged
application.
You can also include several device class tags in the XML tag
and
alarm
are also always returned. You can use the
corresponds to the Acknowledged function in the web
Controlling the KVM switch via XML
off
) or outside (
<monitor>
.
G&D DP1.4-MUX2-NT · 38
alarm
on
) the