6.9

Jump frequency - Avoiding frequency resonance

 : Jump frequency
 : Jumping width
• Function
Resonance due to the natural frequency of the mechanical system can be avoided by jumping the
resonant frequency during operation. During jumping, hysteresis characteristics with respect to the jump
frequency are given to the motor.
Output frequency [Hz]
Jump frequency ()
[Parameter setting]
Title
Jump frequency

Jump width

Note 1: During acceleration and deceleration, the operation frequency jumps do not occur.
Frequency setting signal
0
Function
0.0- (Hz)
0.0-30.0 (Hz)
F-21
Jump width ()
Adjustment range
E6581595
6
Default setting
0.0
0.0