efesotomasyon.com -Toshiba inverter,drive,servo,plc
6.15 2nd acceleration/deceleration
6.15.1 Switching acceleration/deceleration time 1 and 2
:Acceleration time 2
:Deceleration time 2
: Acceleration/deceleration 1 and 2 switching frequency
• Function
Acceleration and deceleration times can be set individually. Select from the following two methods for
selecting and switching.
1) Switching by frequency
2) Switching by terminal
Title
Acceleration time 2
Deceleration time 2
1) Switching according to frequency (automatically switching from the set frequency
to the acceleration/deceleration time) )
Title
Acceleration/deceleration 1 and 2
switching frequency
Output frequency [Hz]
Set frequency
Function
Function
0
(1)
(2)
(1) Acceleration at ramp of
acceleration time
(2) Acceleration at ramp of
acceleration time
F-41
Adjustment range
0.0 ∼ 3000 (sec)
0.0 ∼ 3000 (sec)
Adjustment range
0.0 (disabled),
0.1-
(3)
(3) Acceleration at ramp of
acceleration time
(4) Acceleration at ramp of
acceleration time
E6581595
Standard defaults
10.0
10.0
Standard defaults
0.0
(4)
Time [s]
6