Note: The following parameters are not displayed in this auh, even if they are the most recent changes.
5.2

Setting a parameter using the guidance function

()
 : Guidance function
5
Guidance function ():
The guidance function refers to the special function of calling up only functions necessary to set up
the inverter in response to the user's needs. When a purpose-specific guidance is selected, a
group of parameters needed for the specified application (function) is formed and the inverter is
switched automatically to the mode of setting the group of parameters selected. You can set up the
inverter easily by simply setting the parameters in the group one after another. The guidance
function () provides four purpose-specific guidance.
Title

Note: 1 is for manufacturer's settings. Do not change the settings.
Parameter
display
MODE

MODE

MODE

 (Operation frequency of operation panel),  (Guidance function),  (Automatic
acceleration/deceleration),  (Torque boost setting macro function),  (Default setting), 
(Checking the region setting),  (Prohibition of change of parameter settings)
Function
Guidance function
Press the MODE key to return to the parameter setting mode
"."
After that you can press the MODE key to return to the status
monitor mode or the standard monitor mode (display of operation
frequency).
Adjustment range
0:-
1: - Note 1
2: Preset speed guidance
3: Analog input signal guidance
4: Motor switching guidance
5: Motor constant setting guidance
E-2
E6581595
Default setting
0