Disassembly; Removing Electric Connection; Disassembling The Main Body Of Q.home Ess Hyb-G2 - Q CELLS Q.VOLT-G2 HYB-4.6kW.1.1 Installation Manual

Hide thumbs Also See for Q.VOLT-G2 HYB-4.6kW.1.1:
Table of Contents

Advertisement

12. Disassembly

12.1 Disassembly
CAUTION
Risk of injury due to the heavy weight of the Q.HOME
Make sure to have at least two persons move this system.
CAUTION
Lethal hazards may be caused by high voltages in the Q.HOME
CAUTION
Lethal hazards may be caused by voltage spikes if the positive and negative terminal of
the Battery are shorted by conductive metals.
Stand by for 40 minutes to complete discharging in the system.
CAUTION
When transporting the Q.HOME
(Overweight).

12.1.1 Removing Electric Connection

• Push down the DC disconnect switch in the distribution box.
• Push down the AC circuit breaker in the distribution box.
• Stand by for 40 minutes to complete discharging in the system.
• Remove the AC connection terminal in the main body of the Q.HOME
• Remove the PV connection terminal in the main body of the Q.HOME
• Remove the communication cable from the Q.HOME
• Remove the energy meter.
12.1.2 Disassembling the Main Body of Q.HOME
• Check to make sure that the communication connection line and the external electrical cable
are removed from the Battery and product.
• Open the bottom cover of this product.
• Disconnect AC, Load and Battery connections from the INVERTER.
• Remove all communication lines from the INVERTER.
• Remove the BMS communication cable from the Battery.
• Close the INVERTER and the bottom cover of the Battery.
• Place the INVERTER and Battery in the packing box upside down. Work with at least two persons (Overweight).
• Remove the bottom bracket. This process is the reverse order of the installation process.
107
I
Disassembly
ESS HYB-G2!
+
ESS HYB-G2, work with at least two persons
+
ESS HYB-G2.
+
ESS HYB-G2.
+
ESS HYB-G2.
+
ESS HYB-G2
+
ESS HYB-G2!
+

Advertisement

Table of Contents
loading