Symptom Two - Solution Pump Will Not Operate
Note: Activate the Service Test Mode Program. See the optional program section for instructions. All testing
will be performed in the Service Test Mode Program.
Check for (+) 24V to Bat.(-)
Disconnect the
from the red main harness
pump wire
NO
Repair wiring
pump connector.
connector. Test for
24V
YES
Replace Pump
Check for (-) 24V at the A1
Replace A1
Control Board wire J1-6
Control Board
GRN/BLK to Bat (+)
Check for (-) 24V to
Repair GRN/BLK wire
Bat.(+) from the GRN/BLK
main harness pump
connector.