Fayat Group CP1200 Instruction Manual page 80

Table of Contents

Advertisement

Fig. Cab
1.
Filters (2x)
2.
Bolts (3x)
Fig. –Alternator belt
Fig. – Tensão da correia do alternador
Fig. – Expansion tank
76
1 2 1
Replace the cab air filter
The filter is located at the front of the cab.
Remove three bolts and the protective plastic.
Remove the filters and replace them with new ones.
It may be necessary to replace them more frequently if the
machine is working in a dusty environment.
Check the alternator belt
With the machine stopped, check for cracks in the belt tensioner
arm.
Check the belt on the pulley location, it must be centered.
Inspect the belt daily, search for cracks, if any, replace it
immediately.
Change the engine coolant
1. Open the expansion tank cap.
2. Drain the engine coolant system through the cooler valve
drain.
3.
Use a proper container to collect the coolant (with 3.69 gal
or 14 liters of capacity).
4812325556EN
Scheduled maintenance
Use a step ladder to reach the filter (1). The filter
can also be accessed by the window at the right
side of the cab.
For more detailed information on inspection and
replacement belts refer to the engine
Caution! Risk of severe burns!
Wait until the engine temperature cools down to
122 F (50°C) before removing the coolant tank
cap or draining the coolant system.
NEVER open the coolant tank cap when the
engine is hot.
Be careful when draining the product. Use gloves
and protective goggles.
TAKE CARE OF THE ENVIRONMENT: All used
coolant shall be properly collected and store for
subsequent recycling. Do not dispose of the
coolant on the ground, sewage system or other
place which can harm the environment.