Laser Continuous Low Power Mode >Lm,Tl,X*<Cs><Cr - Safran LRF 6042 Manual

Table of Contents

Advertisement

LRF 6042 Integrator Manual
8.6.3
Laser continuous low power mode >LM,Tl,x*<CS><CR>
This command initiates a continuous low power laser emission at a wavelength of 1550 nm (typical).
The module provides this functionality for alignment purposes only (no range is measured).
The possible inputs for parameter x:
 x=0  OFF state
 x=1  lowest power
 x=...
 x=6  highest power
All emission levels are Class 1 eye safe and presents no risks for SWIR cameras.
Laser continuous low power mode
Command
Inputs
>LM,Tl,x*<CS><CR>
>LM,Tl,1*E2<0D>
>LM,Tl,0*E1<0D>
Response
Outputs
--
Example of a laser continuous low power mode command transaction:
Host  LRF Module
Command frame:
LRF Module  Host
Acknowledge frame:
Prompt:
The operator performs alignment. Afterwards, the emission shall be deactivated.
Host  LRF Module
Command frame:
LRF Module  Host
Acknowledge frame:
Prompt:
INTEGRATOR MANUAL LRF 6042 917657- A
Confidential & Proprietary  SAFRAN VECTRONIX AG – All rights reserved
Description
Low power continuous laser emission with parameter x power level.
Example with x=1 (lowest emitting power).
Example to switch off.
Description
No response expected.
Table 5: Laser continuous low power mode command
>LM,Tl,1*E2<0D>
>AC*84<0D>
<
>LM,Tl,0*E1<0D>
>AC*84<0D>
<
Public: 02.2022
Page: 35/64

Advertisement

Table of Contents
loading

Table of Contents