LRF 6042 Integrator Manual
8.6.7
Block range request >LM,Mb,x*<CS><CR>
This command initiates a set of x range measurements with a repetition frequency of 1 Hz.
The maximum value of the parameter x is 65535.
Ongoing block measurement can be stopped by sending the command with the parameter x=0.
Block range request command and response
Command
Inputs
>LM,Mb,x*<CS><CR>
>LM,Mb,2*D2<0D>
Response
Outputs
>LM,Mb,range1,range2,range3*<CS><CR>
>LM,Mb,range1,range2,range3*<CS><CR>
>LM,Mb,v0004280,R000E301,R000E301*42<0D>
>LM,Mb,v0004276,R000E301,R000E301*47<0D>
Example of a successful Block Range Request command transaction:
Host  LRF Module
Command frame:
LRF Module  Host
Acknowledge frame:
Response frame:
Prompt:
INTEGRATOR MANUAL LRF 6042 917657- A
Confidential & Proprietary  SAFRAN VECTRONIX AG – All rights reserved
Table 9: Block range request command
>LM,Mb,2*D2<0D>
>AC*84<0D>
>LM,Mb,
v0004280,R000E301,R000E301*62<0D>
>LM,Mb,
v0004280,R000E301,R000E301*62<0D>
<
Description
Block range request with parameter x ranges.
Example with x=2 ranges.
Description
Response of LRF with parameter x=2.
Example with parameter x=2.