Table 100-20: Fault Indications - Operator Level - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

PW 6xx7
Machine area
Heating
Power supply
System faults

Table 100-20: Fault Indications - Operator Level

Indication
HEATING SYSTEM FAULT!
Call Service Department if
restart does not work.
HEATING SYSTEM FAULT!
Switch off main switch. Call
Service Department.
POWER CUT! Program stop.
Press the start button.
Coding plug fault! Call
Service Department if restart
does not work.
"Data fault! Limited function."
"Operating data module
defective."
"Data fault! Limited function."
"Loading module defective."
"Data fault! Limited function."
"Language module
defective."
"Data fault! Limited function."
"Dispensing module
defective."
"Data fault! Limited function."
"Water recycling module
defective."
"Data fault! Limited function."
"Flow meter module
defective."
"Card fault." "Card inserted
incorrectly in card reader."
Data fault. Call Service
Department if restart does not
work.
"Operating data memory
module is full." "After
pressing start, operating data
will be overwritten."
Warning symbol (triangle with
exclamation mark) in front of
program name
Lock symbol in front
of program name or "Program
blocked" may also be
displayed
65
Technical Information
Notes
Control has registered an NTC sensor short or
open circuit after a disinfection program has started
with the Thermostop setting Disinfection. If a
disinfection program is running, the control stops it
for safety reasons.
Control registers that both heating-dry protection
contactors (1 and 2) have cut out. Both heating
contactor contacts have fused together. Machine is
filled via 3 inlet valves to maximum level and
program in operation is stopped.
Electronic module has registered a power supply
break > 100 ms. It saves program state and details
of any settings made in programming mode in
backup memory. When power is reapplied, data is
restored and a power interruption is indicated in
display. If Start is pressed, program continues from
stage previously reached.
Coding plug for setting model or heating defective
or has contact problems.
Operating data module defective.
Loading module defective.
Language module defective.
Dispensing module defective.
Water recycling module defective
Flow meter module defective.
Chip card defective or inserted incorrectly.
Checksums faulty. Either program, operating
system, EW 235, EZL 235, clock module, language
module, operating data, multiple position payment
system (IK6), program memory card or backup
comparison (data security).
Operating data memory module is full. Memory
capacity exhausted.
Until ID 846 only; not applicable from ID 1000.
Checksum fault. Affected program is faulty. Delete
program and reload it using Miele Profitronic M
programming and archiving software. Alternatively,
reload program with a chip card.
Program is blocked. Machine is in Allow machine
state. Only approved programs can be selected
and started.