Miele PW 6 7 Series Technical Information page 56

Table of Contents

Advertisement

Technical Information
MDU fault #
F4142
F4143
F4144
F4145
F4146
F4147
F4148
F4149
F4150
F4151
Possible cause
Notes
FEHLER_HEIZSYST
Electrically heated machine.
EM_TGS_SPEICHER
During a program and during a
N
heating phase only one or no
heating-dry protection contact is
closed (relay contact 13, 14 on
1K1/1 and/or 2K1/1). If control
registers a temperature
increase of 5°C via NTC sensor
after 3 min, no fault is indicated.
Heating-dry protection contacts
defective.
FEHLER_THERMOS
Overriding safety time of 80 min
TOP
exceeded in Thermostop.
Heating defective. NTC sensor
defective.
Door lock switch S3
Door lock locking has not been
does not switch or
registered even though 2
motor thermostat F3
locking attempts have been
has tripped.
carried out. Check N1L_ST3,
A2, S3.
FEHLER_TUERSCH
5 unsuccessful attempts to
LOSS_ENTRIEGELU
unlock door have been carried
NG
out
FEHLER_TUERSCH
Clean/Soiled side machine.
LOSS_TUER_OEFF
Door opening unsuccessful 30 s
NEN
after pressing door button.
FEHLER_TUERSCH
Clean/Soiled side machine.
LOSS_TUER_SCHLI
Door closing unsuccessful 30 s
ESSEN
after closing door
FEHLER_TUERFREI
Unlocking door at program end
GABESIGNAL
or after program end with power
interruption not possible. Check
switch S5, B-14, wiring, and
communication from frequency
converter.
Fault - Emergency
During a program in operation
door release. Door
the door has been opened.
opened
L_door signal (signal from S1 to
ELP 235, plug N1L_ST37,
contact marking) missing. Open
circuit, contact fault.
FEHLER_NOTENTRI
After program stop due to an
EGELUNG_TUER_G
emergency door release, the
ESCHLOSSEN
door is closed again. L_door
signal (signal from S1 to ELP
235, plug N1L_ST37, contact
marking) missing. Open circuit,
intermittent, contact problems.
No level increase
300 s of water intake without
within 5 min
level increase ≥ 10 mm wc.
Water intake blocked. Analog
pressure sensor (ADS on ELP
235) defective. Air path from
suds container, air trap, hose,
branch piece, B1-14, imbal-
ance sensor, hose to analog
pressure sensor leaking. Drain
valve does not close.
56
PW 6xx7
Indication in EW 235
Fault/Information
display
No display
Fault
"HEATING SYSTEM
Fault
FAULT! Call the
service department if
restart does not work."
"DOOR LOCK FAULT!
Fault
Call the service
department if restart
does not work."
"DOOR LOCK FAULT!
Fault
Call the service
department if restart
does not work. Use
emergency door
release."
"DOOR LOCK FAULT!
Fault
Call the service
department if restart
does not work."
"DOOR LOCK FAULT!
Fault
Call the service
department if restart
does not work."
"DOOR LOCK FAULT!
Fault
Call the service
department if restart
does not work."
After a program has
Fault
started: "Emergency
door release. Close the
door and press start."
After program has
Fault
stopped: "Emergency
door release program
stop. Press start."
"WATER INLET
Fault
FAULT! Call the
service department if
restart does not work."