Figure 100-3: Coding Example: 10-6-4 = Pw 6107, Electric Heating; Table 100-11: Signal Allocation - Coding Plug N1L_St19 On Elp 235; Table 100-12: Coding Plugs For Different Models, Without Heating; Table 100-13: Heating-Type Coding Without Model - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

Technical Information
Contact on N1L_ST19
10
9
8
7
6
5
4
3
2
1

Table 100-11: Signal Allocation - Coding Plug N1L_ST19 on ELP 235

Model
PW 6107
PW 6137
PW 6167
PW 6207

Table 100-12: Coding Plugs for Different Models, Without Heating

Without heating
Electric heating
High-pressure steam, direct
High-pressure steam, indirect
Low-pressure steam, direct

Table 100-13: Heating-Type Coding without Model

Figure 100-3: Coding Example: 10-6-4 = PW 6107, Electric Heating

Wiring diagram
designation
GND
COD 9
COD 8
COD 7
COD 6
COD 5
COD 4
COD 3
COD 2
COD 1
Coding plug connections
Contact Cod 4 with GND
Contact Cod 5 with GND
Contact Cod 1 with Cod 4 with GND
Contact Cod 1 with Cod 3 with GND
Heating
Coding plug connections
Cod 6 with 7 with 8 with GND
Cod 6 with GND
Cod 8 with GND
Cod 6 with 8 with GND
Cod 6 with 7 with GND
40
PW 6xx7
Notes
Common ground (GND) connection for all coding
Future option
Heating type coding
Heating type coding
Heating type coding
Model coding
Model coding
Model coding
Model coding
Model coding
Notes
10 kg machine
13 kg machine
16 kg machine
20 kg machine
Notes
Special model