Table 100-71: Flow Rate Programming - Miele PW 6 7 Series Technical Information

Table of Contents

Advertisement

PW 6xx7
Service mode (service level)
3
Service settings
1
Basic settings
2

Table 100-71: Flow Rate Programming

Make a selection with the multifunction selector switch and confirm with the
OK button.
The Back button can be pressed to go back one menu level.
Save service messages by pressing and releasing the Save button.
The Back button quits without saving and goes back one menu level.
Programming the allocation of water valves to valve blocks: Each valve block
can be allocated up to 4 water valves. This is important for quantity control
during water intake because of the total intake quantity of a valve block or
what quantity of water really flows into the suds container when each valve is
activated. Example: Valve block 1 with an intake limit of 20 L/min at the valve
block intake is allocated valves K1, K2, K3 each with maximum flow rate 10
L/min. When valves K1, K2 and K3 are activated together, theoretically 3 x 10
Water inlet
1
Flow rate
Display
K1
K1: xx,x L/min
K2
K2: xx,x L/min
K3
K3: xx,x L/min
K4
K4: xx,x L/min
K6
K6: xx,x L/min
KH
KH: xx,x L/min
KD
KD: xx,x L/min
W1
W1: xx,x L/min
W2
W2: xx,x L/min
WD
WD: xx,x L/min
105
Technical Information
Explanation
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 10 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 10 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 2.5 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 2.5 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set the flow rate for this valve from 1 L/min to 50
L/min in 0.5 L/min steps. Standard setting 0 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set the flow rate for this valve from 1 L/min to 50
L/min in 0.5 L/min steps. Standard setting 32 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 16 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 10 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 10 L/min.
For calculating water quantity in program blocks and
complete programs for consumption data collation.
Set flow rate for this valve from 1 L/min to 50 L/min
in 0.5 L/min steps. Standard setting 16 L/min.