L/min flow into the suds container. However, because the total quantity of
water at the valve block is limited to 20 L/min, then even though valves K1,
K2 and K3 are all open, only 20 L/min water will flow into the suds container
(flow equally divided into 3 x 6.66 L/min = 20 L/min).
Service mode (service level)
3
Service settings
1
Basic settings
2

Table 100-72: Valve Block Programming

Make a selection with the multifunction selector switch and confirm with the
OK button.
The Back button can be pressed to go back one menu level.
Save service messages by pressing and releasing the Save button.
The Back button quits without saving and goes back one menu level.
Programming the allocation of water valves to valve blocks: Each valve block
can be allocated up to 4 water valves. Each water valve may only be
allocated once (K1, for example, cannot be allocated to valve block 1 and
valve block 3 at the same time).
Service mode (service level)
3
Service settings
1
Basic settings
2
Water inlet
2
Valve block
Display
Valve
Valve block 1
block 1
Valve
Valve block 2
block 2
Valve
Valve block 3
block 3
Valve
Valve block 4
block 4
Valve
Valve block 5
block 5
Water inlet
2
Valve block
Display
Valve
Valve
block
block 1
Valve
block 1
Valve
Valve
block
block 2
Valve
block 2
Valve
Valve
block 3
block 3
106
Explanation
This valve block can be allocated up to 4 water
valves from a list of possible options (e.g., K1).
Selection procedure must be repeated for each
desired valve (i.e. up to 4 times) as appropriate.
This valve block can be allocated up to 4 water
valves from a list of possible options (e.g., W1).
Selection procedure must be repeated for each
desired valve (i.e. up to 4 times) as appropriate.
This valve block can be allocated up to 4 water
valves from a list of possible options (e.g., K6).
Selection procedure must be repeated for each
desired valve (i.e. up to 4 times) as appropriate.
This valve block can be allocated up to 4 water
valves from a list of possible options (e.g., K1).
Selection procedure must be repeated for each
desired valve (i.e. up to 4 times) as appropriate.
This valve block can be allocated up to 4 water
valves from a list of possible options (e.g., K1).
Selection procedure must be repeated for each
desired valve (i.e. up to 4 times) as appropriate.
Explanation
Valve 1:
Select and allocate each of the following valve
Valve 2:
options once only: "No", "K1", "K2", "K3", "K4",
"K6", "KH", "KD", "W1", "W2", "WD", "Dispenser
Valve 3:
flushing". "No" = no valve allocated.
Valve 4:
Valve 1:
Select and allocate each of the following valve
Valve 2:
options once only: "No", "K1", "K2", "K3", "K4",
"K6", "KH", "KD", "W1", "W2", "WD", "Dispenser
Valve 3:
flushing". "No" = no valve allocated.
Valve 4:
Valve 1:
Select and allocate each of the following valve
Valve 2:
options once only: "No", "K1", "K2", "K3", "K4",
"K6", "KH", "KD", "W1", "W2", "WD", "Dispenser
Valve 3:
flushing". "No" = no valve allocated.
Valve 4:
PW 6xx7