PW 6xx7
MDU fault #
F4253
F4254
F4255
F4256
F4257
F4258
F4259
F4260
F4261
F4262
F4263
F4264
Possible cause
Notes
FEHLER_FU_TRIP,
Washer. Fault in EFU 235. Fault
EFU fault, short
registered from frequency
circuit
converter control EFU. Short
circuit, total current in circuit >
47A for longer than 62.5 µs.
Impermissibly high drive motor
current.
FEHLER_FU_UEBE
Fault registered from frequency
RSPANNUNG,
converter control EFU 235.
EFU fault, excess
Voltage in EFU 235 circuit is too
voltage
high ( > 850VDC).
FEHLER_FU_UNTE
Fault registered from frequency
RSPANNUNG,
converter control EFU 235. EFU
EFU fault, low voltage
235 input voltage < 320V
Phase is missing. Fuse has
tripped.
FEHLER_FU_UEBE
Washer. Fault registered from
RLASTUNG,
frequency converter control
EFU fault, overload,
EFU 235. EFU 235 circuit
too much power at
power > 5kW for an
EFU
impermissible period of time.
FEHLER_FU_NETZU
Washer. Fault registered from
NTERBRECHUNG,
frequency converter control
EFU fault, power
EFU 235. Input voltage EFU
failure
235 is missing.
FEHLER_FU_OFFSE
Washer. Fault registered from
T, EFU fault, current
frequency converter control
sensors
EFU 235. EFU 235 current
monitoring indicating
impermissible values. One or
more current sensors defective.
FEHLER_FU_UEBE
Fault registered from frequency
RTEMPERATUR_IG
converter control EFU 235. The
BT, EFU fault, excess
temperature at the heat sink of
temperature at power
the power output stage (IGBT)
output stage
of the EFU 235 has exceeded
90°C (194°F).
FEHLER_FU_UEBE
Fault registered from frequency
RSTROM,
converter control EFU 235.
EFU fault, excess
Peak motor current at M5 > 38A
drive motor current
for time t > 1.5 s.
FEHLER_FU_TACH
Fault registered from frequency
O, EFU fault, tacho
converter control EFU 235.
signal
Tacho impulse from
tachogenerator G1 is missing or
detected as faulty.
FEHLER_FU_ID,
Fault registered from frequency
EFU fault, unknown
converter control EFU 235. EFU
control ID
control does not recognize the
software ID of the ELP 235.
FEHLER_FU_PARIT
Fault registered from frequency
Y, EFU fault,
converter control EFU 235. A
communication
parity fault (a type of
fault between EFU
transmission fault occurring with
and ELP
data transmission) has occurred
during communication between
EFU 235 and ELP 235.
FEHLER_FU_OVER
Fault registered from frequency
RUN, EFU fault,
converter control EFU 235. An
communication fault
overrun fault (a type of
between EFU and
transmission fault occurring with
ELP
data transmission) has occurred
during communication between
EFU 235 and ELP 235.
61
Technical Information
Indication in EW 235
display
.
eff
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
"Drive system fault!"
Fault/Information
"Drive system fault!"
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault