PW 6xx7
No.
22
23
24
25
26
Program Step
Basic Options
Level stop 2
No
Same as Wash
Wash time 2
time 1
Cooldown
No
Same as Wash
Wash time 3
time 1
Program stop 2
No
75
Technical Information
Setting Options
Notes
Water inlet takes place at same
time as Dispensing phase 2,
No
Agitation from level and Wash
time 2.
Water is first taken in until
programmed water level is
reached. Control interrupts
further program operation until
this has occurred and then starts
Yes
drum agitation with settings
made for Agitation from level.
Wash time 2 starts after
programmed level 2 has been
reached or after time set with
Agitation from level has
elapsed.
See Wash time 1
See Wash time 1
No controlled suds cooling takes
No
place.
Controlled suds cooling takes
place at 3°C/min. Valve
programmed for Intake path 2 is
opened intermittently to take in
water until max. level in machine
Automatic
is reached. Drainage then takes
place down to wash level via
valves set in Drainage path 1.
Water intake and drainage are
then repeated alternately until
suds temperature has dropped to
45°C.
Controlled suds cooling takes
place. Valve programmed for
Intake path 2 is opened
intermittently to take in water until
max. level in machine is reached.
Drainage then takes place down
to wash level via valves
programmed in Drainage path 1.
User-defined
Water intake and drainage are
then repeated alternately until
selected suds temperature has
been reached. Suds temperature
can be set between 20°C and
95°C in 1°C-steps. Cooling rate
can be set between 1°C/min and
20°C/min in 1°C steps.
See Wash time 1
See Wash time 1
No
No stop during program
Program always stops at this
Yes
point. Program is continued by
pressing Start.