MDU fault #
F4166
F4167
F4168
F4169
F4170
F4171
F4172
F4173
F4174
F4175
F4176
F4177
F4178
F4179
F4180
F4181
F4182
F4186
F4187
Possible cause
Notes
Fault - Weighing
During a wash program,
system during
a fault has been detected in the
program sequence
loading module (weighing
system). Check the plug
connection between EB 230
plug 65X and ELP 235 plug
N1L_ST22.
Fault - Power
ELP 235 has registered power
interruption
break ≥ 100 ms.
FEHLER_CHIPKART
EW 235 has registered that chip
E_SLT
card is inserted but ELP 235
cannot create connection.
FEHLER_CHIPKART
EW 235 has registered that chip
E_BAE
card is inserted but EW 235
cannot create connection.
After ID 2286: Internal
After ID 2286: FEHLER_
fault control with data
BACKUP_SERVICEEINSTELL
backup of service
UNGEN. Checksum to monitor
settings.
data backup of service settings
is incorrect.
After ID 2286: Internal
Internal fault control. After ID
fault control with data
2286: FEHLER_ BACKUP_
backup of list of
EA_ZUORDNUNG. Checksum
input/output
to monitor data backup of list of
allocations.
input/output allocations is
incorrect.
After ID 2286: Internal
Internal fault control. After ID
fault control with data
2286: FEHLER_
backup of list of
BACKUP_SYSTEMKOMPONE
system components.
NTEN. Checksum to monitor
data backup of list of system
components is incorrect.
FEHLER_PROGRAM
Internal fault control. Fault in list
MLISTE
of programs.
Internal fault
Internal fault control.
FEHLER_INTERRUP
Internal fault control.
T
FEHLER_TASK
Internal fault control, internal
time exceeded for communica-
tion between ELP 235 & EW
235.
Internal fault
Internal fault control EW 235.
Internal fault
Internal fault control EW 235.
Internal fault
Internal fault control EW 235.
Internal fault
Internal fault control EW 235.
Internal fault
Internal fault control EW 235.
Internal fault
Internal fault control EW 235.
Fault - Flash card
Fault when copying data flash
copying
card to ELP 235.
Internal fault
Internal fault control.
58
PW 6xx7
Indication in EW 235
Fault/Information
display
"Data fault. Limited
Fault
function. Loading
module defective."
"Voltage interruption!
Fault
Program stop. Press
the start button."
"Card fault. Card
Fault
inserted incorrectly in
card reader."
"Card fault. Card
Fault
inserted incorrectly in
card reader."
After ID 2286: "Data
Fault
fault! Call the service
department if restart
does not work."
After ID 2286: "Data
Fault
fault! Call the service
department if restart
does not work."
After ID 2286: "Data
Fault
fault! Call service
department if restart
does not work."
Fault
Fault
No display
Fault
Fault
"Data fault! Call service
Fault
dept. if restart does not
work."
No display
Fault
"Data fault! Call service
Fault
dept. if restart does not
work."
"Data fault! Call service
Fault
dept. if restart does not
work."
"Data fault! Call service
Fault
dept. if restart does not
work."
"Data fault! Call service
Fault
dept. if restart does not
work."
"Copying fault! Memory
Fault
card could not be
copied."
"Data fault! Call service
Fault
dept. if restart does not
work."