Model
Measurement
wavelength range
Wavelength resolution
Display wavelength interval
Wavelength precision
±0.3 nm (center-of-gravity wavelength mercury cadmium lamp: 435.8 nm, 546.1 nm, 643.8 nm)
Spectrum wavelength width
Measurement angle
(electrically switchable)
Luminance range with
guaranteed accuracy
0.0001 to 100,000 cd/m
(Light source A)
Minimum
ø5 mm (ø1 mm when using
measurement diameter
Minimum objective distance
Minimum luminance display
Minimum spectral
radiance display
Luminance: Accuracy
*1
(Light source A)
5%
Luminance:
1.5%
Repeatability
0.7%
(2σ)
*2
0.25% (0.003 to 0.05 cd/m
(Light source A)
0.15% (0.05 to 100,000 cd/m
x: ±0.002, y: ±0.002 (0.001 to 0.05 cd/m
Chromaticity:
x: ±0.0015, y: ±0.001 (0.05 to 100,000 cd/m
Accuracy
*1
u': ±0.0014, v': ±0.0011 (0.001 to 0.05 cd/m
(Light source A)
u': ±0.0014, v': ±0.0006 (0.05 to 100,000 cd/m
x: 0.0030, y: 0.0035 (0.001 to 0.003 cd/m
x: 0.0010, y: 0.0015 (0.003 to 0.1 cd/m
x: 0.0006, y: 0.0006 (0.1 to 0.2 cd/m
Chromaticity:
x: 0.0004, y: 0.0004 (0.2 to 100,000 cd/m
Repeatability
(2σ)
*2
u': 0.0024, v': 0.0014 (0.001 to 0.003 cd/m
(Light source A)
u': 0.0009, v': 0.0006 (0.003 to 0.1 cd/m
u': 0.0005, v': 0.0002 (0.1 to 0.2 cd/m
u': 0.0003, v': 0.0002 (0.2 to 100,000 cd/m
Polarization error
2% or less (400 to 780 nm): 1° and 3% or less (400 to 780 nm): 0.2° and 0.1°
Integration time
0.005 to 92 seconds (NORMAL mode); 0.005 to 16 seconds (FAST mode)
Minimum of 1 second or less (MANUAL mode) to approx. 190 seconds (NORMAL mode)
Measurement
Standalone
or maximum of approx. 242 seconds (MANUAL mode)
time
Communication
*3
Approx. 0.07 seconds (when MANUAL mode, 33.333 ms and INTELLIGENT DARK function are set)
Color space mode
L
x y, L
v
Color matching
CIE1931 (2°), CIE1964 (10°), CIE170-2:2015 (PA2°, PA10°), any isochromatic function (measurement
software supported)
functions
Optical frequency
Detectable range: Luminance of 10 to 5,000 cd/m
detection function
Detection accuracy: ±0.015 Hz; Detection time: Approx. 3 seconds
Interfaces
USB 2.0, RS-232C
Operating
temperature and
5 to 30°C, 80% RH max. (no condensation)
humidity range
Storage temperature
0 to 35°C, 80% RH max. (no condensation)
and humidity range
Power
Dedicated AC adapter (100 to 240 V , 50/60 Hz)
Power consumption
Approx. 20 W
Size
158 (W) × 262 (H) × 392 (D) mm
Weight
Approx. 7.0 kg
*1: Average value of 10 measurements in the NORMAL mode, at temperature of 23°C ± 2°C and maximum relative humidity of 65%.
*2: Average value of 10 measurements in the NORMAL mode, at temperature of 23°C ± 2°C and maximum relative humidity of 65%.
*3: When the USB cable is connected. Excluding the time required for display and shutter opening/closing. In an environment
designated by KONICA MINOLTA such as a PC.
CS-3000HDR SPECTRORADIOMETER
5 nm max. (half width value)
2
0.0025 to 2,500,000 cd/m
ø1 mm (ø0.2 mm when using
closeup lens)
350 mm (55 mm when using closeup lens)
± 5 % (0.0001 to 0.0004 cd/m
± 2 % (0.0004 to 10,000,000 cd/m
(0.0001 to 0.004 cd/m
2
)
5%
(0.0004 to 0.001 cd/m
2
)
1.5%
(0.001 to 0.003 cd/m
2
)
0.7%
2
)
0.25% (0.075 to 1.25 cd/m
2
)
0.15% (1.25 to 2,500,000 cd/m
2
)
x: ±0.002, y: ±0.002 (0.025 to 1.25 cd/m
2
)
x: ±0.0015, y: ±0.001 (1.25 to 2,500,000 cd/m
2
)
u': ±0.0022, v': ±0.0011 (0.025 to 1.25 cd/m
2
)
u': ±0.0014, v': ±0.0006 (1.25 to 2,500,000 cd/m
2
)
x: 0.0030, y: 0.0035 (0.025 to 0.075 cd/m
2
)
x: 0.0010, y: 0.0015 (0.075 to 2.5 cd/m
2
)
x: 0.0006, y: 0.0006 (2.5 to 5 cd/m
2
)
x: 0.0004, y: 0.0004 (5 to 2,500,000 cd/m
2
)
u': 0.0024, v': 0.0014 (0.025 to 0.075 cd/m
2
)
u': 0.0009, v': 0.0006 (0.075 to 2.5 cd/m
2
)
u': 0.0005, v': 0.0002 (2.5 to 5 cd/m
2
)
u': 0.0003, v': 0.0002 (5 to 2,500,000 cd/m
u' v', L
TΔuv, XYZ, spectrograph, main wavelength, excitation purity
v
v
102
380 to 780 nm
0.9 nm/pixel
1.0 nm
0.2°
2
ø0.5 mm (ø0.1 mm when using
closeup lens)
0.00002 cd/m
2
1.0 × 10
–9
W/(sr·m
2
·nm)
2
)
2
)
(0.0025 to 0.01 cd/m
2
)
5%
(0.01 to 0.025 cd/m
2
)
1.5%
(0.025 to 0.075 cd/m
2
)
0.7%
2
)
0.25% (0.3 to 5 cd/m
2
)
0.15% (5 to 10,000,000 cd/m
2
)
x: ±0.002, y: ±0.002 (0.1 to 5 cd/m
2
)
x: ±0.0015, y: ±0.001 (5 to 10,000,000 cd/m
2
)
u': ±0.0022, v': ±0.0011 (0.1 to 5 cd/m
2
)
u': ±0.0014, v': ±0.0006 (5 to 10,000,000 cd/m
2
)
x: 0.0030, y: 0.0035 (0.1 to 0.3 cd/m
2
)
x: 0.0010, y: 0.0015 (0.3 to 10 cd/m
2
)
x: 0.0006, y: 0.0006 (10 to 20 cd/m
2
)
x: 0.0004, y: 0.0004 (20 to 10,000,000 cd/m
2
)
u': 0.0024, v': 0.0014 (0.1 to 0.3 cd/m
2
)
u': 0.0009, v': 0.0006 (0.3 to 10 cd/m
2
)
u': 0.0005, v': 0.0002 (10 to 20 cd/m
2
)
u': 0.0003, v': 0.0002 (20 to 10,000,000 cd/m
2
and emission frequency of 10 to 200 Hz.
0.1°
0.01 to 10,000,000 cd/m
2
closeup lens)
(0.01 to 0.04 cd/m
2
)
(0.04 to 0.1 cd/m
2
)
(0.1 to 0.3 cd/m
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)
2
)