Download Print this page
Konica Minolta CS-2000 Brochure
Hide thumbs Also See for CS-2000:

Advertisement

Quick Links

Easy operation with color LCD screen and simple operation panel
The color LCD screen and operation panel are located at the rear of the instrument.
The simply arranged operation panel enables intuitive selection of necessary
functions.
Color LCD screen
Color space mode
Menu screen
screen
Lv
30 . 79
c d
m
2
x
0 . 3211
y
0 . 3404
Lv
30 . 79
c d
m
2
T
6027K
duv
+0 . 005
Data Management Software CS-S10w Professional
With this software, the CS-2000 and CS-2000A can be controlled from a personal computer to display measured data in
various graphs or lists, to transfer data to spreadsheet software, or to copy-and-paste data. CS-S10w offers various data
management, analysis and evaluation options to assist in research and development or quality control.
Template showing xy and u'v' chromaticity diagrams
Multiple data objects can be copied
and pasted to spreadsheet software.
• Windows
trademark of Microsoft Corporation in the
USA and other countries.
• Pentium
in the USA and other countries.
Display
Spectral graph, spectral data list, chromaticity diagram
System requirements
Color space mode L
xy, L
u'v', L
T uv, XYZ, dominant wavelength,
OS
v
v
v
excitation purity, scotopic luminosity
Calculation
Four basic arithmetic operations and
function processing of spectral data
CPU
Mode selection
Normal mode, contrast mode, RGB mode, RGB &
Memory
contrast mode, object color mode
Instrument control Averaging measurement, interval measurement, user calibration
Hard disk 60 MB or more of free space for installation
Data management Reading/saving files; managing data by using folders;
Display
creating, saving and reading templates with various graphs
Other
designed and laid-out by users; displaying data with graphs
Data evaluation
Observer/illuminant setting, color rendering property evaluation,
statistic value display for each folder, box tolerance setting,
multiple point setting for display evaluation, non-uniformity
(mura) display, contrast display, polygonal tolerance setting
Major specifications of CS-2000/2000A
Model
Wavelength range
Wavelength resolution
Display wavelength bandwidth
Wavelength precision
Spectral bandwidth
Measuring angle (selectable)
Measurement luminance
CS-2000
range (Standard light source A)
CS-2000A
Simple
Minimum measuring area
operation
Minimum measuring distance
Minimum spectral radiance display
The desired function
Accuracy: Luminance
can be called
(Standard light source A)*1
intuitively.
Accuracy: Chromaticity
(Standard light source A)*1
Easy
Repeatability: Luminance (2σ)
connection
(Standard light source A)*2
via USB
Repeatability: Chromaticity (2σ)
(Standard light source A)*2
Accuracy: Chromaticity
(Standard light source A)*1
Repeatability: Luminance (2σ)
(Standard light source A)*2
Repeatability: Chromaticity (2σ)
(Standard light source A)*2
Polarization error
Integration time
Measurement time
Color space mode
(Standard accessory)
Interface
Operating temperature/
humidity range
Storage temperature/humidity range
Power
Current consumption
Size
Weight
Outer dimensions
Filter thread
diameter: ø52
®
is a trademark or registered
SAFETY PRECAUTIONS
®
is a trademark of Intel Corporation
For correct use and for your safety, be sure to read the instruction manual
before using the instrument.
Always connect the instrument to the speci ed power supply voltage.
Improper connection may cause a re or electric shock.
Windows
2000 Professional SP4,
®
Windows
®
XP Professional SP2/×64 Edition,
Windows
®
Vista Business 32-bit/64-bit
Pentium
®
III 600 MHz equivalent or faster
128 MB or more
(256 MB or more recommended)
1024 x 768, 256 colors minimum
CD-ROM drive for installation, USB port
for instrument connection
2007 KONICA MINOLTA SENSING, INC.
CS-2000/2000A
380 to 780 nm
0.9 nm/pixel
1.0 nm
±0.3 nm (Median wavelength: 435.8 nm, 546.1 nm, 643.8 nm; Hg-Cd lamp)
5 nm or less (half bandwidth)
0.2°
0.1°
0.003 to 5,000 cd/m
2
0.075 to 125,000 cd/m
2
0.3 to 500,000 cd/m
0.0005 to 5,000 cd/m
2
0.0125 to 125,000 cd/m
2
0.05 to 500,000 cd/m
ø5 mm
ø1 mm
ø0.5 mm
(ø1 mm when using close-up lens)
(ø0.2 mm when using close-up lens)
(ø0.1 mm when using close-up lens)
350 mm (55 mm when using close-up lens)
1.0x10
W/sr, m
, nm
-9
2
±2%
x,y :±0.003
(0.003 to 0.005 cd/m
2
)
x,y : ±0.003 (0.075 to 0.125 cd/m
2
)
x,y : ±0.003 (0.3 to 0.5 cd/m
x,y :±0.002
(0.005 to 0.05 cd/m
)
x,y : ±0.002 (0.125 to 1.25 cd/m
)
x,y : ±0.002 (0.5 to 5 cd/m
2
2
x
: ±0.0015
x
: ±0.0015
x
: ±0.0015
(0.05 cd/m
or more)
(1.25 cd/m
or more)
2
2
(5 cd/m
y
: ±0.001
y
: ±0.001
y
: ±0.001
0.4%
(0.003 to 0.05 cd/m
2
)
0.4%
(0.075 to 1.25 cd/m
2
)
0.4%
(0.3 to 5 cd/m
0.3%
(0.05 to 0.1 cd/m
)
0.3%
(1.25 to 2.5 cd/m
)
0.3%
(5 to 10 cd/m
2
2
0.15% (0.1 to 5,000 cd/m
2
)
0.15% (2.5 to 125,000 cd/m
2
)
0.15% (10 to 500,000 cd/m
0.002 (0.3 to 0.5 cd/m
0.002 (0.003 to 0.005 cd/m
2
)
0.002 (0.075 to 0.125 cd/m
2
)
0.001 (0.005 to 0.1 cd/m
2
)
0.001 (0.125 to 2.5 cd/m
2
)
0.001 (0.5 to 10 cd/m
0.0006 (0.1 to 0.2 cd/m
2
)
0.0006 (2.5 to 5 cd/m
2
)
0.0006 (10 to 20 cd/m
0.0004 (0.2 to 5,000 cd/m
2
)
0.0004 (5 to 125,000 cd/m
2
)
0.0004 (20 to 500,000 cd/m
x,y :±0.002
(0.001 to 0.05 cd/m
2
)
x,y : ±0.002 (0.025 to 1.25 cd/m
2
)
x,y : ±0.002 (0.1 to 5 cd/m
x
: ±0.0015
x
: ±0.0015
x
: ±0.0015
(0.05 cd/m
2
or more)
(1.25 cd/m
2
or more)
(5 cd/m
y
: ±0.001
y
: ±0.001
y
: ±0.001
1.5%
(0.0005 to 0.001 cd/m
)
1.5%
(0.0125 to 0.025 cd/m
)
1.5%
(0.05 to 0.1 cd/m
2
2
0.7%
(0.001 to 0.003 cd/m
2
)
0.7%
(0.025 to 0.075 cd/m
2
)
0.7%
(0.1 to 0.3 cd/m
0.25% (0.003 to 0.05 cd/m
)
0.25% (0.075 to 1.25 cd/m
)
0.25% (0.3 to 5 cd/m
2
2
0.15% (0.05 to 5,000 cd/m
2
)
0.15% (1.25 to 125,000 cd/m
2
)
0.15% (5 to 500,000 cd/m
x: 0.003 y: 0.0035 (0.1 to 0.3 cd/m
x: 0.003 y:0.0035 (0.001 to 0.003 cd/m
2
)
x: 0.003 y: 0.0035 (0.025 to 0.075 cd/m
2
)
x: 0.001 y:0.0015 (0.003 to 0.1 cd/m
2
)
x: 0.001 y: 0.0015 (0.075 to 2.5 cd/m
2
)
x: 0.001 y: 0.0015 (0.3 to 10 cd/m
x,y: 0.0006 (0.1 to 0.2 cd/m
)
x,y: 0.0006 (2.5 to 5 cd/m
)
x,y : 0.0006 (10 to 20 cd/m
2
2
x,y: 0.0004 (0.2 to 5,000 cd/m
2
)
x,y: 0.0004 (5 to 125,000 cd/m
2
)
x,y : 0.0004 (20 to 500,000 cd/m
1°: 2% or less (400 to 780 nm); 0.1° and 0.2°: 3% or less (400 to 780 nm)
Fast: 0.005 to 16 sec.; Normal: 0.005 to 120 sec.
1 sec. minimum (Manual mode) to 243 sec. maximum (Normal mode)
L
xy, L
u'v', L
T∆uv, XYZ, spectral graph, dominant wavelength, excitation purity, scotopic luminosity (with CS-S10w Professional)
v
v
v
USB 1.1
CS-2000 : 5 to 35°C, relative humidity 80% or less with
CS-2000A : 5 to 30°C, relative humidity 80% or less with
no condensation
no condensation
0 to 35°C, relative humidity 80% or less with no condensation
AC adapter (100 - 240 V
, 50/60 Hz)
Approx. 20 W
158 (W) x 200 (H) x 300 (D) mm (Main unit), ø70 × 95mm (Lens)
6.2 kg
*1: Average of 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less.
*2: 10 measurements in Normal mode at a temperature of 23±2°C and a relative humidity of 65% or less.
Reference
Mounting screw: M5,
for measuring
Depth: 6.5
distance
Mounting screw: M5,
120.5
129
95.7
229.5
ø15
Depth: 6.5
6
Optical axis
Positioning pin hole (1):
Positioning pin hole (2):
ø5, Depth: 4
Depth: 4
70
170
Tripod screw (ø3/8-inch screw)
58.5
300
190.4
392
The speci cations and drawings given here are subject
to change without prior notice.
- If you have any questions about speci cations, please
contact your Konica Minolta representative.
Certi cate No : YKA 0937154
Registration Date : March 3, 1995
9242-4892-10 BACDPK
5
2
2
2
)
)
2
2
or more)
2
)
)
2
2
)
)
2
2
)
2
)
)
2
2
)
2
or more)
)
2
2
)
)
2
2
)
2
)
2
)
)
2
2
)
(Units: mm)
Certi cate No : JQA-E-80027
Registration Date : March 12, 1997
Printed in Japan
Spectroradiometer
NEW
CS-2000/2000A
The world's top-level capability spectroradiometers make
further advances with addition of second model to lineup.

Advertisement

loading
Need help?

Need help?

Do you have a question about the CS-2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Konica Minolta CS-2000

  • Page 1 - If you have any questions about speci cations, please For correct use and for your safety, be sure to read the instruction manual contact your Konica Minolta representative. before using the instrument. Always connect the instrument to the speci ed power supply voltage.
  • Page 2 Measurements of various objects are possible by selecting Comparison of * Comparison with Konica Minolta's previous model CS-1000 for target luminance of 0.1 cd/m World's top level capability to detect extremely the best-suited measuring angle. repeatability * The y-axis indicates the logarithm when the average of the CS-2000 measured values is assumed to be 1.

This manual is also suitable for:

Cs-2000a - autreCs-2000a