Introduction

This instrument is a high-accuracy spectroradiometer designed to measure luminance and chromaticity
up to super-low luminance regions. Carefully read this manual before using it.
Packaging materials
Be sure to save all packaging materials (corrugated cardboard boxes, pads and plastic bags)
supplied with the purchase. This is a precision measuring instrument. Use supplied packaging
materials to minimize shocks and vibrations in case this instrument needs to be transported for
purposes such as maintenance in KONICA MINOLTA's factories.
Should any of these packaging materials be lost or broken, please contact the nearest
KONICA MINOLTA-authorized service facility.

Notes on Use

Be sure to use this instrument properly. Use of this instrument in ways other than those specified in this
manual may result in risk of injury, electric shock, instrument damage, or other problems.

Operating Environment

 The AC adapter (AC-A312G) supplied as a standard accessory is designed specifically for use
indoors. Do not use it outdoors.
 Do not disassemble this instrument as it is composed of precision electronic components.
 Use this instrument at rated voltage of 100-240 V . Connect the AC power cord to the AC outlet
with the rated voltage and frequency of 100-240 V (50/60 Hz). Connected voltage should not be
outside the range of ±10% of nominal.
 This instrument corresponds to a Pollution Degree 2 product (instruments used mainly in
manufacturing plants, laboratories, warehouses or equivalents.). Use the instrument in
environments not exposed to metallic dust and condensation.
 This instrument corresponds to an Overvoltage Category I product (instruments connected to a
circuit with measures taken to limit excessive overvoltage to a suitably low level).
 This instrument and the AC adapter are EMC Class B products. Use of the instrument and the AC
adapter in home environments may cause radio interference. Users may be required to take
appropriate measures in such cases.
 This instrument complies with Electrical equipment for measurement, control and laboratory use - EMC
(Electromagnetic Compatibility) requirements - Part 1: General requirements (EU Harmonized
Standards EN 61326-1:2021). Conformity verification is performed under KONICA MINOLTA's test
conditions in an INDUSTRIAL ELECTROMAGNETIC ENVIRONMENT specified in the relevant
harmonized standards. The limit of performance degradation when subjected to continuous disturbance
during immunity testing is up to twice KONICA MINOLTA's repeatability specifications (Lv, x, y).
 Take care not to allow foreign substances like water and metal to penetrate the instrument.
Operating it in such a state is extremely dangerous.
 Do not use this instrument in places exposed to direct sunlight or near a heating appliance. Doing so
may cause the internal temperature of the instrument to greatly exceed the ambient temperature,