12
If you want to measure ground leakage current, press I4 current probe
trigger to open the jaw and fully enclose the ground line "G".
5. Press "POWER" key to select (P1, Q1, S1, PF1), (P2, Q2, S2, PF2)
and (Pt, Qt, St, PFt) measured values.
6. Frequency (Hz), Phase Angle (Θ), Ground Leakage Current (I4) and Power
Factor (pF) measurement :
 Press "PFΘ" key to cycle shows the PF and Θ measured values.
 Press "Hz I4" key to cycle shows the Hz and I4 measured values.
7. Voltage and Current THDR THDF measurement:
Please refer to section 4-1-12 "THD" key description.
8. Voltage and Current waveform harmonic measurement:
Please refer to section 4-1-25 "
9. Power Maximum/Minimum measurement:
Please refer to section 4-1-10 "MAX" key description.
10. Energy measurement:
 Press "ENERGY" key, the "Pt", "Qt", "St" and "PFt" or "ψt" annunciator
and energy integrate start time are displayed. The energy integrate value
and the current time will be continuous accumulate.
a). KW displays KWh
b). KVAR displays KVARh
c). KVA displays KVAh
 Press "STOP" key to stop energy accumulated and the "HOLD"
annunciator is displayed.
User Manual
MAG." key description.