Transport; Packaging; Storage; Installation, Setup And Normal Operation - Kollmorgen AKD 2G-S Series Installation Manual

Hide thumbs Also See for AKD 2G-S Series:
Table of Contents

Advertisement

4.1 Transport

Transport the AKD2G in accordance with IEC 61800-2 as follows:
Transport only by qualified personnel in the manufacturer's original recyclable packaging.
l
NOTICE: Avoid shocks while transporting.
l
Vibration/Shock: AKD2G is tested for environmental class 2M1 of IEC 60721-3-2.
l
Store at or below maximum stacking height 8 cartons (see "Storage" (➜ # 23))
l
Transport only within specified temperature ranges:
l
-25 to +70 °C, max. rate of change 20 K/hour, class 2K3.
Transport only within specified humidity:
l
max. 95% relative humidity at +40°C, no condensation, class 2K3.
The drives contain electrostatically sensitive components that can be damaged by incorrect handling.
Electrostatically discharge yourself before touching the drive. Avoid contact with highly insulating
materials, such as artificial fabrics and plastic films. Place the drive on a conductive surface.
If the packaging is damaged, check the unit for visible damage. Inform the shipper and the manufacturer of any
damage to the package or product.

4.2 Packaging

The AKD2G packaging consists of recyclable cardboard with inserts and a label on the outside of the box.
Model
AKD2G-Sxx-6V03 to 6V12
AKD2G-Sxx-7V03 to 7V12
AKD2G-Sxx-7V24
Mating connectors are not included in the package of a standard drive.
Mating connectors are included when the drive is ordered with accessories (append "-A" to the model
number).

4.3 Storage

Store the AKD2G in accordance with IEC 61800-2 as follows:
Store only in the manufacturer's original recyclable packaging.
l
Store at or below maximum stacking height 8 cartons.
l
Store only within specified temperature ranges: -25 to +55 °C, max.rate of change 20 K/hour, class 1K4.
l
Storage only within specified humidity: 5 to 95% relative humidity, no condensation, class 1K3.
l
Store in accordance with the following duration requirements:
l
Less than 1 year: without restriction.
l
More than 1 year: capacitors must be re-formed before setting up and operating the drive. Re-forming
l
procedures are described in the KDN (Forming).

4.4 Installation, setup and normal operation

Installation and setup information are given in this manual:
Mechanical installation (➜ # 47)
l
Electrical installation (➜ # 51)
l
Setup (➜ # 162)
l
Normal operation tested for environmental class 3K3 according to IEC 61800-2 (➜ # 33).
The manufacturer of the machine defines the necessary end user expertise based on the risk assessment for the
machine and describes the requirements for normal operation based on the application.
Package (mm) HxWxL
158 x 394 x 292
158 x 394 x 292
158 x 394 x 292
Kollmorgen | kdn.kollmorgen.com | June, 2023
AKD2G-S Installation Manual, Safety 1
Total Weight (kg)
4.2
4.3
7.6
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Akd2g-s 6v03s seriesAkd2g-s s6v06s seriesAkd2g-s s6v12s seriesAkd2g-s s6v03d seriesAkd2g-s s6v06d seriesAkd2g-s s7v03s series ... Show all

Table of Contents