2. On the Device page, you may enter values for the parameters indicated in
Note
Web Page Item
Relay Settings
Activate Relay with DTMF Code
Relay Pulse Code
Relay Pulse Duration (in seconds)
Relay Activation Code
Relay Deactivation Code
Activate Relay During Ring
Activate Relay During Night Ring
Activate Relay While Call Active
Activate Relay on InformaCast
Time Settings
Enable NTP
NTP Server
Timezone
Current Time
Operations Guide
The question mark icon (
after the Toggle Help button is pressed
Table 2-10. Device Page Parameters
Description
Activates the relay when the DTMF Activation Code is entered on the
phone during a SIP call with the device. RFC2833 DTMF payload types
are supported.
DTMF code used to pulse the relay when entered on a phone during a
SIP call with the device. Relay will activate for Relay Pulse Duration
seconds then deactivate. Activate Relay with DTMF Code must be
enabled. Enter up to 25 digits (* and # are supported).
The length of time (in seconds) during which the relay will be activated
when the DTMF Relay Activation Code is detected. Enter up to 5 digits.
Activation code used to activate the relay when entered on a phone
during a SIP call with the device. Relay will be active indefinitely, or until
the DTMF Relay Deactivation code is entered. Activate Relay with DTMF
Code must be enabled. Enter up to 25 digits (* and # are supported).
Code used to deactivate the relay when entered on a phone during a SIP
call with the device. Activate Relay with DTMF Code must be enabled.
Enter up to 25 digits (* and # are supported).
When selected, the relay will be activated for as long as the device is
ringing. When Auto-Answer Incoming Calls is enabled, the device will not
ring and this option does nothing.
When selected, the relay will be activated as long as the Nightringer
extension is ringing.
When selected, the relay will be activated as long as the SIP call is active.
Check this box to activate the relay while receiving a page from
Informacast. The relay will activate on a start command and deactivate on
a stop command.
Sync device's local time with the specified NTP Server.
Use this field to set the address (in IPv4 dotted decimal notation or as a
canonical name) for the NTP Server. This field can accept canonical
names of up to 64 characters in length.
Enter the tz database string of your timezone.
Examples:
America/Los_Angeles
America/New_York
Europe/London
America/Toronto
See
for a full list of valid strings.
Displays the current time.
931976A
Installing the InformaCast Enabled Paging Amplifier
) in the following table shows which web page items will be defined
.
https://en.wikipedia.org/wiki/List_of_tz_database_time_zones
InformaCast Enabled Paging Amplifier Setup
Table
CyberData Corporation
33
2-10.
Need help?
Do you have a question about the 011403 and is the answer not in the manual?