Display Of The Life Of The Inverter Parts (Pr. 255 To Pr. 259) - Mitsubishi Electric FR-E720-0.1KNC Instruction Manual

Table of Contents

Advertisement

Useful functions

5.21.2 Display of the life of the inverter parts (Pr. 255 to Pr. 259)

Degrees of deterioration of main circuit capacitor, control circuit capacitor, cooling fan and inrush current limit circuit can
be diagnosed by monitor.
When any part has approached the end of its life, an alarm can be output by self diagnosis to prevent a fault.
(Use the life check of this function as a guideline since the life except the main circuit capacitor is calculated
theoretically.)
For the life check of the main circuit capacitor, the alarm signal (Y90) will not be output if a measuring method of (4) is
not performed.
Parameter
Number
255
Life alarm status display
Inrush current limit circuit
256
life display
Control circuit capacitor life
257
display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 197)
REMARKS
Since repeated inrush currents at power ON will shorten the life of the converter circuit, frequent starts and stops of the
magnetic contactor must be avoided.
214
Name
Initial Value
100%
100%
100%
Setting
Range
Displays whether the control circuit capacitor,
main circuit capacitor, cooling fan, and each parts
0
(0 to 15)
of the inrush current limit circuit has reached the
life alarm output level or not. (Reading only)
Displays the deterioration degree of the inrush
(0 to 100%)
current limit circuit.
(Reading only)
Displays the deterioration degree of the control
(0 to 100%)
circuit capacitor.
(Reading only)
Displays the deterioration degree of the main
circuit capacitor.
(0 to 100%)
(Reading only)
The value measured by Pr. 259 is displayed.
Setting "1" and turning the power supply off starts
the measurement of the main circuit capacitor life.
0, 1
0
When the Pr. 259 value is "3" after powering on
(2, 3, 8, 9)
again, the measuring is completed.
Writes deterioration degree in Pr. 258.
Description