Operation Via Cc-Link Communication And Its Settings; Cc-Link Communication Setting (Pr.541 To Pr.544) - Mitsubishi Electric FR-E720-0.1KNC Instruction Manual

Table of Contents

Advertisement

5.4

Operation via CC-Link communication and its settings

Purpose
To make CC-Link communication
settings
To select the operation at
CC-Link communication error
occurrence
To select the error reset operation at
inverter failure
To limit parameter writing via
CC-Link communication
5.4.1

CC-Link communication setting (Pr.541 to Pr.544)

Set the CC-Link communication details such as station number and baud rate.
Parameter
Number
Frequency command sign
541
selection (CC-Link)
Communication station number
542
(CC-Link)
543
Baud rate selection (CC-Link)
544
CC-Link extended setting
(1)
Station number setting (Pr. 542)
Use Pr. 542 Communication station number (CC-Link) to set station number of the inverter. Set this parameter within the
range of 1 to 64.
NOTE
Use different station numbers for different devices. (If different devices have the same station number, the
communication cannot be performed properly.)
Connection example
Programmable controller
CC-Link
master module
Station 00
REMARKS
• Set consecutive numbers for the station numbers. (Do not skip a number in sequence like "station number 1 - station number 2-
station number 4".)
The station number does not have to match with the physical connection sequence. (There is no problem with having the physical
connection sequence like "station number 1 - station number 3 - station number 4 - station number 2".)
• One inverter occupies one station. (One remote device station)
• "L.ERR" LED flickers if the setting is changed. When power is switched ON again, the setting value is applied and the LED
turns OFF.

Operation via CC-Link communication and its settings

Communication station number setting
Baud rate setting
Frequency command sign selection
Extended CC-Link setting
Communication error execution waiting time
Communication error occurrence count
display
Stop method at communication error
Communication reset selection
Communication EEPROM write selection
Initial
Name
Value
0
1
0
0
Inverter No.1
remote I/O station
Remote device station
(occupies one station)
Station 01
Station 02
Parameter that should be Set
Setting
Range
A plus/minus sign added to the frequency
Without
0
command inverts the forward and reverse
sign
start commands.
Make selection of sign for the frequency
1
With sign
command from RWw1.
1 to 64
Sets the station number.
0
156kbps
1
625kbps
2
2.5Mbps
Sets the transmission speed.
3
5Mbps
4
10Mbps
0, 1, 12,
Extends the remote register function.
14, 18
Inverter No.2
Remote device station
Station 03
Number of stations connected is 4.
Refer to Page
Pr.541 to Pr.544
105
Pr.500 to Pr.502
107
Pr.349
110
Pr.342
110
Description
Inverter No.3
Remote device station
Station 04
5
105