Function assignment of external terminals and CC-Link communication virtual terminals
Setting
Signal
Positive
Negative
logic
logic
64
164
Y64
68
168
EV
80
180
SAFE
81
181
SAFE2 Safety monitor output 2
90
190
Y90
91
191
Y91
93
193
Y93
95
195
Y95
96
196
REM
98
198
LF
99
199
ALM
9999
∗ Note that when the frequency setting is varied using an analog signal or
alternate ON and OFF depending on that varying speed and the timing of the varying speed due to acceleration/deceleration time setting.
(The output will not alternate ON and OFF when the acceleration/deceleration time setting is "0s".)
REMARKS
The same function may be set to more than one terminal.
When the function is executed, the terminal conducts at the setting of any of "0 to 99", and does not conduct at the setting of
any of "100 to 199".
NOTE
Changing the assignment of the terminal Y0 or a virtual terminal of CC-Link communication with one of Pr. 190 to Pr.
192, and Pr. 313 to Pr. 315 (output terminal function selection) may affect other functions. Set parameters after confirming
the function of the terminal Y0 and virtual terminals.
168
Function
During retry
Output during retry processing.
24V external power
The signal is output while the main circuit power supply is
supply operation
off and the 24V power is supplied externally.
Safety monitor output
Output while safety stop function is activated.
The signal is output when no internal safety circuit failure
(E.SAF, E.6, E.7, E.CPU) exists.
Output when any of the control circuit capacitor, main
Life alarm
circuit capacitor and inrush current limit circuit or the
cooling fan approaches the end of its service life.
Fault output 3
Output when a fault occurs due to the internal circuit failure
(power-off signal)
of the inverter wiring mistake.
Average current value and maintenance timer value are
Current average value
output as pulses.
monitor signal
The signal can not be set in Pr. 192 RX7 function selection .
Maintenance timer
Output when Pr. 503 rises to or above the Pr. 504 setting.
signal
Remote output
Output to the terminal when a value is set to the parameter.
Output when an alarm (fan failure or communication error
Alarm output
warning) occurs.
Output when the fault occurs.
Fault output
The signal output is stopped when the fault is reset.
No function
Operation
of the operation panel, the output of the SU (up to frequency) signal may
Refer
Related
to
Parameter
Page
Pr. 65 to
188
Pr. 69
24
24
Pr. 255 to
214
Pr. 259
170
Pr. 555 to
218
Pr. 557
Pr. 503,
217
Pr. 504
Pr. 495,
174
Pr. 496
Pr. 244,
107,
Pr. 500
213
170